From:

Holonich, Joseph To:

Shakun, Matthew A Cc:

Stattel, Richard

Subject:

Information on Components Date:

Monday, September 23, 2019 3:33:00 PM Matt/Warren In its review of the Common Q Equipment Qualification Summary Qualification Report, staff noticed that several new hardware components were tested but were not included in the topical report (Table 11-1). Since they were included in the equipment under test, staff is willing to add them as qualified hardware components in the safety evaluation if Westinghouse would agree to add them to Table 11-1 of the topical report when the Dash A version is published. Here is a list of these components.

  • Fiber Optic Modem OZDV 114B Power Supply Equipment:
  • 24Vdc/20A 2320966
  • 24Vdc/10A 2320953
  • 48Vdc/5A 2320937
  • 12Vdc/15A 2320940
  • Input Line Filter Please let us know if this works. Also, please note that I plan to place this email in ADAMS and make it public.

Joe