Notice of Violation from Insp on 790404-11
ML19263E756
Person / Time
Site: Byron  
Issue date: 04/18/1979
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19263E754 List:
References
50-454-79-06, 50-454-79-6, 50-455-79-06, 50-455-79-6, NUDOCS 7906250136
Download: ML19263E756 (1)


Text

.

Appendix A NOTICE OF VIOLATION Commonwealth Edison Company Docket No. 50-454 Docket No. 50-455 Based on the inspection conducted on April 4-11, 1979, it appears that certain of your activities are in noncompliance with NRC require-ments, as noted below. This item is an infraction.

10 CFR 50, Appendix B, Criterion XIII, states, in part, that " Measures shall be established tc control the handling, storage, shipping, cleaning and preservatiot. of material and equipment to prevent damage or deterioration." Byron Topical Report No CE-1-A commits Commonwealth Edisen to the QA requirements of WASH 1309, " Guidance on Quality Assurance Requirements during the Construction Phase of Nuclear Power Plants," and through WASH 1309 to the requirements of ANSI N45.2.2.

ANSI N45.2.2, Section 6.1.2(4), states, in part, "ltems shall be stored on cribbing.

." Section 3.5.1 of ANSI N45.2.2 states, in part, " Caps and plugs shall be used.. to protect weld end preparations." Section 6.4.2(1) of ANSI N45.2.2 states, in part,

" Items in storage shall have all... closures intact." Section 6.5 of ANSI N45.2.2 states, in part, " Items released from storage.

shall be inspected and cared for in accordance with the requirements of Section 6 of this standard.

Contrary to the above, on April 4, 1979, at Level 365 near coordinates M-11 in the Auxiliary Building, the inspector observed twelve centain-ment piping penetration assemblies which were improperly stored.

The twelve assemblies were not on dunnage. On the three largest assemblies, the flued head weld prep areas were not protected, and the assemblies were supported on the concrete floor by the edges of the weld prep areas.