l Aoril 26, 1979 SECY-79-297 NUCLEAR REGULATORY CoMMisslCN l
INFORMATION REPORT For:
The Comissioners From:
James R. Shea, Director Office of International Programs 4
Thru:
Executive Director for Operations
Subject:
APPLICATION FOR EXPORT OR IMPORT LICENSE DATED 4/20/79, XSNM01500, HEU TO DENMAP"
Purpose:
To infonn the Comission of the receipt of a license application.
Discussion:
Enclosed for the information of the Comission are copies of an application for a license for which Comission action will ultimately be necessary. Copies of the application have been placed in the Public Occument Room.
i Comissioners are requested to advise the staff of any particular issues or information which they can identify at this stage and which they wish included in the staff's analysis.
.0<_EA.
a
~
JhesR.SheD0irector i
Office of International Programs 7
Enclosure:
w Subject Application 2288 ;26
Contact:
GG0plinger (492-7866)
JDLee (492-7984)
DISTRIBUTION Ccmissioners Comission Staff Offices Exec. Dir. for Opers.
Secretariat 790601ofyg 4
3 s
I i
k
__m1.m.
Gb
~
~
I l.
April 20,1979 I
i Mr. N. Pccre j
Nuclear Pegulatcry Ccnnissicn Office of Intermticnal Pregra:::s 7735 Old Gecrgetan Pcad Bethesda, Marylard 20014 Pe: W License Applicatien - 21 Fef: 79-132/01 Ord-279) 4
Dear Mr. M:
cre:
Atached please find an W. Lice se Applicatien fer your handling.en the fellc h.g:
l 15.038 Kg U, cen*=i'd g 14.030 Kg U235 l
a"H c M te 93.30 percent U235.
?2.rJdng ycu in advance fer ycur help and cecperatien.
Sincerely, kf /$"
n-l Vicki Matsen l
Assistant Manager - Washingten Cpemtiens i
Enclesure: Original E.U.S.
Original Fescetr Checklist 2288
.,27 i
' CE:*/20
..l. %:
i
'.5b l-s ? E
\\ 5$
k i
=.. ~..
...s..~..;,
CNE SKYLNE PLAC2. :203 LIESBURG 8'KE. FALLS CHURCH. VIAGINA 2 041 TELEPHCNE. 700 4 20 2450. CABLI: *RANSNUC 83CN = ?!LIX: !).3443 7 70529D //P
~~
~
.[
t i
e i
4 1
acRM NRc-r u.s. NuctaAR R ecucATcRv ccMantasioN 4,.aviosvcao
'[ eye'R ete APPLICATION FOR CCENSE TO EXPCRT NUCLEAR MATERIAL ANO ECulPMENT /seelarnesons o,e Aewrw/
i l
. aseuCANrs. om ra se.eeucAricale. ae.ucaar s ausaa.cs 12. NRc YS.5/ f) r) /M,J l //9A 1 h.,
t. weava =o.
. le. occmar
- i
/4 usa 4/23/79 tut-279 79-132/01 uss ANo a I Ris A su.peu sR s A,M,s, en e,,coR as,t l
1 ArcuCANrs NAMs ANo acoRass i mis
.C e s o
.r
, e --
. =Aus Trar.sr r-' ='. I::c.
U.S.D.O.E.
. sraser.coas sa
. =.Me g
J Crm Derir.a Place. 5205 te-7 Pika e/o Coodiear A - d-Cers.
. c:rv svare zieCoos
- o. svaseT *ocassa l
F=11* C:urds VA 22041 leuta One
- e. r a i.4e-c= a =w ea R w - a -e- - o mm,
. cir, svare siacoca (703) 820-2450 Piket:n CH 45661 l
S. 81Rsf &*.tP98 TNT G. PiNA4. 5MtPMENT 7. AreUCANrs cQNTRACWayL PROPCs40 UCENat
- 9. uJ.QEP ARTMENT 08 444RGY 3
sCHEDutED SCHEDULED OglivtRV OATS l SXPeRaftCas oaf t CONTR AC? NC ne rne.n, 4
One year fr:rs l 2 be c'.eter ined
- 8. ate of issuancelecre assi=.ed e 6ta
- 11. utfiMAfs aNo use I
is utnMATs ceNsicNse i mis
".e =ar"d e se cf fuel U****"'**
. *e Au a RISO-Pasea:th Establishnmt RISO Will 1m used f:: tt elssnents for the OR-3 Faacter at RISO
- e. seaser.coassa CK-4000
. carv - sr Af e -CGumrav E*@d 't d, Ca.M 11 Est. DATE C# et AS? uSE a
9 j
is. INTtaMSDiart cCNssONEW mes
'11 INTERMEDIATE ENO usE l
. t
.namn
- Lkers Ct H, D-645 Harau, Fei. Pec. cf Ger:a:T/
Nukers shall perf0:2 conversicn of LT5 into U =ietal. Elsi.T.zs Shiward shall :na.~'ar.re
. svasar acosass ard Elsi.T.:e shirvarf fuel elements at trair.czksrq at RISO.
. carv - erAra -Cowara, RISC, Demark
,3,. erf eart ce emsv est 14 INTERMEDIArt CON 1aGNEE R EE IS. ANT RM8DBATE $NQ uS8 i
. NAMS
-'rar.s:sklaar, CrtH.
Ira -=ita fer trans;cr: p.=peses only.
i
- e. svasst acoassa tiu danaue Ecs"*m 6030 T-bei-Earau I.x*ist=iir elarde
',blf ea.
. cirv - stars - Cou=rav
- Fam,
'4. @N'T/
is. est. eArt es einst use IL
- 17. QtSCR PTICM l 18. MAX. ELSMENT 1s. M AX. [20. MAX l 31.
u.rira.,ee. erne.=cw e.e, eave.=sr ase.n er ewenar eneswurcre eswar ew er I
welCMT l
nt. 41 isCTCPt WT. I UNIT Y,
NRC use
.-e t
C:sni:.22 in the
- cf uranit:2 rm+-if.a 15.038 Kg U l93.3%
14.020 "235 Kgs en:-e.ed to a rax::s=2 cf 93.3 percent:
4
- :In O
- 22. COUNTRY OF QRIG4N.-
21 COUNTRY CP CRIGINetNM
' iT4. CCuMTRIEs WMsCM ATTACM i
saaesuAmes at <=
souRC: MAT RIAL
==aRs sNRicMao cR recoucao US
__ __ l
=*
- s. ACQiTIONALINFORMADQN Nwasowese rwrs manys 1
- 2s. Tu sees.euw esmeios maa m se a ereser.e.a r=wv ma riese to, c ee er swees Rec.noaa we mn e..eerw ne.sa.a m.e l
l en ee a..i.
e
'l27. AuTMcRazss opsictAL l. sa Nag / p2/ 9gp l m a M s g ;'an. w. y.
Ra
"'-+ s ;;iar..0 I
4 2288
- 28 79Com
+. '-~ c t ~ *lQ l
, ;. q : i
.,s.
.r
~'
.s, P R L.d a c ecyt e =r= uc- '"
- "--. r = - ". - - : '
e
---Inc m:t c:= t m'- -
- ..u,-
n r
u,... u_.i...... m..,..., - - -. - - -
.u..
D1:a t = n.,1. __..;
- 1. M me of Facility:
Reactor DR 3.
Riso. Cenmark
- 2. Quantity of Uranium Requected (Kgs):
15 kg
- 3. Inrichnent in the I:otope U-235 (6):
9 3
- 4. Sale or Toll Ihriching:
Toll enrichment i
- 5. current core Leading (rgs of U-235):
2.559 kg
- 6. Current Power Lovel (I.~a*th):
10 MW
- 7. Criticality and Full operating Pow Dates and Power Rating (if requ<:-t inv.v s new fccility):
- 6. N::ne of convertor and Fabriestor f Fuel:
converter Nukem a
Fabricator: Elsinore Shievard (Workshoe at Riso site)
- 9. Breakdown of Fuel Inventory (Kga of U-235):
32.094 kc l
- b. Amount of U-235 in storage in completed, Unir:2diated Pael Ilcmen.::
i.
11.417 kg
- c. A= cunt of U-235 in coro:
2.339,Kg
- d. knount of U-235 in scent Pael storage within the ce=nunity In:1udine chemic:1 I
Re:rocessing Plants, and the Retrocessing schedule for Euch %:cr al:
7298,5 kg
'e. A= cunt of U-235 Leet and/or Censu=ed Euring C erati n of Aieve Fa-11.
3c.JJe,
,& g
- f. A= cunt of U-235 per Fuel Ilemen :
1~0 g
- g. Averzic Core Life:
4 month
- h. Avers.cc Le.si Time for Ccnversien and Pt.el Fabricati:n if Ocnv
-w cr.d f. r -
catica is to be Dene A': read:
2288 m_
_s__
t n -- n -.- -. -.
I f
l i;
g-==;s
,. !l e
- I
.., oc. ~ -
.!j ii.it i
g l
A?R l~ 7973 t
i l
.2 4
To whom it may concern:
i 4
I End Use Statement I
The undersigned certify that the quantity of 15.038 kgs of urani-um (93.3 per cent U-235 enriched) in the form of UF6 and contai-l ning 14.030 kgs of U-235, which will be furnished to us under a Fixed Commitment Contract with US DOE will be used by us as fol-lows:
NUiGM GmbH, D-645 Hanau, Federal Republic of Germany shall per-form conversion of the UF6 into uranium metal. After conversion, i
Elsinore Shipyard shall manufacture fuel elements at their work-shop at Riso. The fuel elements will be used for insertien into l
the reactor DR 3 at Riso.
1 We authorize Transnuclear Inc., Falls Church, Virginia to apply for the US export license.
i Date: 1979.03.23 Sign.:
- u. n===
2288 330