ML19263C409

From kanterella
Jump to navigation Jump to search
Forwards Rept XN-NF-78-44,Generic Analysis of Control Rod Ejection Transient for Pwrs
ML19263C409
Person / Time
Site: Prairie Island  
Issue date: 02/12/1979
From: Jason White
SIEMENS POWER CORP. (FORMERLY SIEMENS NUCLEAR POWER
To:
Office of Nuclear Reactor Regulation
Shared Package
ML19263C410 List:
References
NUDOCS 7902220078
Download: ML19263C409 (1)


Text

ERON NUCLEAR COMPANY,lnc.

2101 Horn Rapids Road P. O. Box 130, Richland, Weshington 99352 Phone: (509) 943-8100 Telex: 32-6353 February 12, 1979 Director of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.

20555

SUBJECT:

Prairie Island Nuclear Generating Plant Docket No. 50-282; License No. DPR-42 Docket No. 50-306; License No. DPR-60

Reference:

Letter, L. O. Mayer (NSP) to Director of Nuclear Reactor Regulation (NRC) dated December 29, 1978

Dear Sirs:

On December 29, 1978 Northern States Power Company submitted by the Reference letter a li cense amendment request related to use of Exxon Nuclear Company fuel in Prairic Island Units 1 and 2.

Document XN-NF-78-47, entitled "Prairic Island Unit 1 Nuclear Plant C"cle 5 Safety Analysis Report," trans-mitted by the reference letter (Exhibit C), referenced a control rod ejection accident analysis report published by Exxon Nuclear.

By attachment to this letter find forty (40) copics of XN-NF-78-44, entitled "A Generic A'nlysis of tbc Control Rod Ejection Transient for Pressuri::ed Water Reactors

  • transmitted in support of the Reference request.

Sincerely, EXXO" NUCLEAR C05 y '

INC.

Ass A

[

John A. White Reload Licensing JAW:gf Attachments As noted CC:

Mr. Marshall Grotenhuis (NRC)

Mr. Lee 0. Mayer (NSP) h A

790222007s

{t AN AFFILIATE OF EXXON CORPORATION