ML19263C078

From kanterella
Jump to navigation Jump to search
IE Insp Rept 70-1201/78-17 on 781218-20.Noncompliance Noted: Failure to Adjust Matl Accounting Data for Measurement Bias. Details Withheld (Ref 10CFR2.790)
ML19263C078
Person / Time
Site: 07001201
Issue date: 01/04/1979
From: David Jones, Gerald Williams
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML19263C077 List:
References
70-1201-78-17, NUDOCS 7902020293
Download: ML19263C078 (1)


Text

MATaut. TRANSMITTED HEREWITH CONTA M G W i @ A M N f "ag r

y,'

,o, NUCLEAR REGULATORY COMMISSION R ECloN li f (

e r

c 101 M ARIETTA STREET. N.W.

f*

[

ATLANTA, GEORGIA 30303 o

JAN 4 1979 Report No..

70-1201/78-17 Docket No.:

70-1201 License No.: SNM-1168 Safeguards Group:

III Licensee: Babcock and Wilcox Company Commercial Nuclear Fuel Plant Lynchburg, Virginia Inspection conducted: December 18-20, 1978 Inspector:

D. %,Jon/

es i

w

/v

/-U7'f Reviewed by:

/k/aw

.C, H. Williams, thief

/'

Date Material Control and Aycountabylity Section Safeguards Branch

/

Inspection Summary Inspection conducted on December 18-20, 1978 (Report No. 70-1201/78-17)

Areas Inspected: Routine, unannounced inspection of measurements and statis-tical controls associated with nuclear material control and accountability.

The inspection involved 20 inspector-hours onsite by one NRC inspector.

Results:

In the area inspected, one apparent item of noncompliance was identified (Deficiency:

Failure to adjust material accounting data for measurement bias (78-17-01)).

5 -

C pies r 7;,c; copr ls Documen. is not t3 N A

h'eproduced,ith:ut speciUC aporovalofIE II WTGtA1. TRANSMITTED HGEWITH CONTAINS 2.750 IWORMAT10N

'l o 2 0 2 @ 'J 3