(7 77 LICENSEE EVENT REPORT CONTROL BLOCK: l l l l l l l (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

I 6 10 I t8 l9l V l ALICENSEE 7

lNlA l S l 114 l@l15 0 l0 CODE

- 10 LICENSE l0 l0NUMBERl010 l- l0 J025l@l 4l LICENSE 26 ll 1l 1l 1l@lb7 CATSS TYPE JO l l@

CON'T O i 8

y',g l L l@l 0l 5l 0 0] Ol 3 3l8)@l0ll 0l217l9l@lnIi19 loI7 lo80@68 69 EV ENT D ATE 74 75 REPORT D ATE 7 60 61 DOCAET NUYSER EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h 1012 l lDuring the performance of a periodic test, it was discovered that containment isola- I

[ TIT) l tion valve TV-SV-102-1 would not shut fully. This is contrary to T.S. 3.6.3.1. l 0 4 l Containment isolation valve TV-SV-103 was closed and TV-SV-102-1 was restored to l 0 s loperable status within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> as required by the applicable action statement. This O s event is reportable as per T.S. 6.9.1.9.b. I 10171 l I O 8  !

DE CODE SL9CO E COMPONENT CODE SU8 CODE S E l0l91 'lS lD l@ [ Ej@ lB l@ lV l A l L l V l E l X l@ IF l@ lD l@ 20 7 8 9 10 11_ 12 13 18 19

__ SEQUENTI AL OCCURRENCE REPORT REVISION LER i; VENT YE A R REPORT NO. CODE TYPE N O.

O,Rf,P,g'RO u

l719j [---J l0 0l31 l/l 1013 l lL l-] l0 l

,21 22 23 24 26 27 23 29 30 31 32 N ACT ON ON PL NT 1 T HOURf S 3 IT D FO 1 8. S PPLIE MAN FACTURER lX lglXl@

33 34 l35Z l@ lZl@

M l0l0l0l01 3/ 40 lYl@

41 lNl@

42 lAl@ lFl112l5l@

43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h li l0 l lThe cause of the isolation valve not closina is unknown at this time. Immediate I i ij l corrective action was to close TV-SV-103 and submit an emeraency maintenanco rannrt I

, , TV-SV-102-1 was cycled and fully closed 3 times. The valve was returned to coerable I g i i 31 l status within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of the initial failure. I l i 14 I I l 7 8 9 80 STA S  % POWER OTHER STATUS ISCO RY DISCOVERY DESCRIPTION li I s I [E_J@ l 0 [ 9 l 7 l@l NA l lBl@l Feriodic Test l A Tt V e T Y CO TENT RELEASED Of Rt LE ASE AYOUNT OF ACTIVITY LOC ATION OF RELEASE NA l l NA l li lcl 8[Z_J 7 9

@W 10

@l 11 44 45 80 PERSONNEL FXPOSURES NUMBER TYPE DESCRIPTION lij7ll0l0l0l@lZl@l NA l PERSONNELiN;u'g5ES NUMBE R DESCRIP DON 7

i a 6 9 l0l0l0l@l 11 12 NA 80

'osS o' og^J;;^,ylo '^CluTv @ 790202C O Idsj TIEl@l NA l 7 8 9 10 80 2 o ISSUjE

[tt l@DE CRidTION flA l lllIl l I l l I I I ;I 7 8 9 to 68 69 80 &

NAME OF PREPARER PHONE: 703-894-5151

Virginia Electric and Power Company North Anna Power Station, Unit #1

Attachment:

Page 1 of 1 Docket No. 50-338 Report No. LER 79-003/03L-0 Description of Event:

On 1-2-79 during the performance of a periodic test, it was discovered that Containment Isolation Valve TV-SV-102-1 would not fully shut. This is contrary to T.S. 3.6.3.1.

Isolation Valve TV-SV-103 was closed and TV-SV-102-1 was restored to operable status within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> as required by the applicable Action Statement.

This event is reportable as per T.S. 6.9.1.9.b.

Probable Consecuences of Occurrence:

The OPERABILITY of the containment isolation valves ensures that the containment atmosphere will be isolated from the outside environment in the event of a release of radioactive material to the containment atmosphere or pressurization of the containment.

Since the redundant isolation valve TV-SV-103 was operable and secured closed, there was no effect upon the safe operation of the plant. As a res ul t,#-~-

the public health and safety was not endangered.

Cause of Occurrence:

The cause of the Isolation Valve not closing is unknown at this time.

Immediate Corrective Action:

Isolation Valve TV-SV-103 was placed in the closed position with the operating air isolated to prevent valve actuation. An emergency maintenance report was subnitted.

The isolation valve was cycled 3 times and fully closed each time. The valve was returned to operable status within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of the initial failure.

There was no apparent reason discovered for the initial failure of the valve.

Scheduled Corrective Action:

TV-SV-102-1 will be inspected during an appropriate cold shutdown to determine the cause of its failure to operate properly.

Actions Taken to Prevent Recurrence:

Actions to prevent recurrence will be determined pending the inspection stated above.

._ _ _ .