ML19263B956
| ML19263B956 | |
| Person / Time | |
|---|---|
| Site: | Vermont Yankee File:NorthStar Vermont Yankee icon.png |
| Issue date: | 01/08/1979 |
| From: | Charemagne Grimes Office of Nuclear Reactor Regulation |
| To: | Eisenhut D Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 7901250192 | |
| Download: ML19263B956 (4) | |
Text
'
/
I UNITED ST A TES f.. *1
}
NUCLEAR REGULATORY COMMISSION WASHINGTON. D. C. 20555 Ybabf !
JAN 8 1019 MEMORAf4DLH FOR:
D. G. Eisenhut, Acting Assistant Director for Systems and Projects, Division of Operating Reactors FROM:
C. I. Grimes, Task Manager A-7
SUBJECT:
FORTHCCMING MEETING WITH REPRESENTATIVES OF THE MARK I OWNERS GROUP CATE & TIME:
Monday, January 22, 1979 2:00 pm Tuesday, January 23, 1979 8:30 am Wednesday, January 24, 1979 8:30 am LOCATION:
San Jose, CA 1/22/79 GE Pruneyard Towers 1/23-24/79 Hyatt House
~
PURPOSE:
To discuss the Mark I Long Term Program Load Definition Report and related issues. A pro-posed agenda is attached.
ATTENDEES:
NRC - C. Grimes, J. Fair, J. Kudrick, N. Su BNL - G. Maise, J. Ranlet, R. Kosson, C. Tung, C. Economos. A. Sonin (MIT), G. Bienkowski (Princeton)
GE - B. Buchholz, L. Steinert, et. al.
Mark I Owners - TRC Representatives EPRI - C. Sullivan, et. al.
LLL - E. McCauley, et. al.
[ t u ti C. Grimes Task Manager A-7
Enclosure:
As stated cc: see page 2 7901P50/9.L
9 PROPOSED AGENDA January 22, 1979 2:00 - 7 00 pm Discussion of two and three dimensional pool swell test results 1.
2D/30 data comparisons 2.
three dimensional effects 3.
test facility configurational differences 4
effects of vent system orificing 5.
vent flow distributions 6.
pressure integration methodology January 23, 1979 I.
General Program Status Summary 1.
Schedule for submittal of outstanding reports.
2.
Implementation of LDR and plant-unique, analysis content.
3.
Methods for resolution of NRC questions and comments.
II. Ongoing program issues 1.
Downcomer submergence -thermal stratification 2.
FSTF application methodology 3.
Fluid - structure interaction effects 4.
Load definition error and uncertainty III. SRV Discharge Loads 1.
Cuencher parametric testing
- a. 1/4 scale test results
- b. scaling considerations (NEDC 23713) 2.
Monticello quencher test results 3.
Subble phasing 4
Pool temperature limits for quencher 5.
Monticello mixing test results.
IV. Detailed discussion of NRC/ consultant questions and :caments on Mark I Load Definition Report (NEDO 21888).
January 24, 1978 Continuation of NRC/ consultant questions and comments on Mark I Load Definition Report.
s P
-2 DISTRIBUTION:
H. Centon (Q
V. Stello Loca6 POR
- 8. Grimes Docket Files T. Carter OELD 50-10 OI&E (3) 50-219 ACRS (16) 50-247 OSD (3) 50-259/260/269
- 0. Eisenhut 50-324/325 G. Lainas 50-298 G. Knighton 50-249 V. Noonan 50-331 P. Check 50-333 D. Ziemann 50-321 T. Ippolito 50-366 D. Davis 50-263 J. Stolz 50-220 R. Baer 50-293 R. Hartfield 50-277/278 D. Thompson 50-254/265
~'
R. Tedesco (T"TfB W. Butler 50-341 F. Schauer 50-354/355 J. Knight C. Anderson S. Fabic R. Cudlin N. Su R. Bosnak K. Wichman J. Fair C. Grimes H. Shaw
.