Pugat Sound Pcwer i L 7t 00rcany Puget Power 9uec'rg Bdevue Aashrgten 9;tT9 G 4%QJ January 11, 1979 PLN-210 Director of Nuclear Reactor Regulation Attention:

Mr. John F. Stolz, Chief Light Water Reactor Branch No. 1 Division of Project Management U. S. Nuclear Regulatory Commission Washington, D. C.

20555

Subject:

Puget Sound Power & Light Company Skagit Nuclear Power Project, Unit 1 & 2 Docket Nos. 50-522 and 50-523 Letter Report entitled " Subsurface Investigation of Disturbed Glacial Deposits on Lake Cavanaugh Road"

Dear Mr. Stolz:

Submitted herewith please find 6 copies of the above referenced letter report. Although no formal question was directed to the Applicant by the NRC regarding the glacial deposits on Lake Cava-naugh Road, a series of newspaper articles and television news re-ports based upon press releases at about the same time the NRC was informed by the USGS, implied that active faulting could be con-sidered the most likely cause of the deformation in the glacial de-posits. Additionally, an NRC field trip report, dated Novecher 23, 1978, recommended that Puget Power should conduct additional inves-tigations of the feature.

In light of the above, Puget's consultant, Bechtel, investigated the feature in question along Lake Cavanaugh Road and the referenced report represents the results of that inves-tigation.

A closely spaced auger boring program was utilized to define the till layer approximately 40 feet below the local road surface.

No evidence, from the auger holes, could be found that the till layer was offset; the surface of the till is, in fact, remarkably uniform over the interval examined.

h

\\

q 9 01 '2 5 01D 4

PLN-210 Mr. John F. Stol: January 11, 1979 This report is being submitted to the NRC Staff at this time so that review of this report can be pursued in a timely fashion.

Very truly yours,

}

bwr f

F

/

9 i

,e g

/,,' t. - ;(

J. E. Mecca - Manager Nuclear Licensing & Safety Attach.

cc: Correspondence List ASLB Correspondence List USGS (5 copies)

CORRESPONDENCE LIST Mr. Richard L. Black CFSP and F03 NRC Legal Staff c/o E. Stachon & L. Marbet U.

S. Nuclear Regulatory Commission 19142 South Bakers Ferry Road Office of the Executive Legal Director Boring, Oregon 97099 Washington, D. C.

20555 Mr. Roger M. Leed, Esq.

Mr. Richard M. Sandvik, Esq.

Suite 610 Assistant Attorney General 1411 Fourth Avenue Building State of Oregon Seattle, Washington 98101 Department of Justice 500 Pacific Building Mr. Nicholas D. Levis, Chairman 520 S. W. Yamhill Washington State Energy Facility Portland, Oregon 97204 Site Evaluation Council 820 East Fifth Avenue Mr. Richard D. Bcch, Esq.

Olympia, Washington 98504 Rives, Bonyhadi & Drummond 1400 Public Service Building Mr. Robert C. Schofield, Director 920 S. W. 6th Avenue Skagit County Planning Department Portland, Oregon 97204 Room 218 County Administration Building Mr. H. H. Phillips, Esq.

Mount Vernon, Washington 98273 Vice President and Corporate Counsel Portland General Electric Company Mr. Robert Lowenstein 121 S. W. Salmon Lowenstein, Newman, Reis, Axelrad & Toll Portland, Oregon 97204 1025 Connecticut Avenue N. W.

Suite 1214 Russell W.

Busch Washington, D. C. 20036 Attorney for Sauk-Suiattle and Upper Skagit Tribes Mr. F. T. Thomsen 520 Smith Tower Perkins, Cole, Stone, Olsen & Williams Seattle, Washington 98104 1900 Washington Building Seattle, Washington 98101 Donald S. Means Swinomish Tribal Community Box 277 LaConner, Washington 98257

ASLB CORRESPONDENCE LIST Mr. Valentine B. Deale-Esq.

Suite 504 1001 Connecticut Avenue N.W.

Washington, D. C.

20036 Dr. Frank F. Hooper School of Natural Resources University of Michigan Ann Arbor, Michigan 48109 Mr. Gustave A. Linenberger Atomic Safety and Licensing Board Panel U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Mr. Alan S. Rosenthal, Chairman Atomic Safety and Licensing Appeal Panel U. S. Nuclear Regulatory Commission Washington, D. C.

20555