ML19263B443

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 99900401/78-04 on 781113-17 & Notice of Deviation
ML19263B443
Person / Time
Issue date: 11/27/1978
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Etheridge M
ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
Shared Package
ML19263B437 List:
References
REF-QA-99900401 NUDOCS 7901180257
Download: ML19263B443 (2)


Text

_

pe.

' t v "%,

UNITED STATES

/

c, NUCLE AR REGULATORY CCYMISSION

[ },

k REGION IV

{

g ;;'j,,

i 611 RYA?l PLAZA DRIVE, StalTE 1003 a

g Q;j, / 7 AR LINGTON, TE X AS 78011 w

Docket !!o. 99900401/78-04 1

Combustion Engineering, Inc.

Attn: Mr. M. R. Etheridge Vice President General Services 1000 Prospect Hill Road Windsor, Connecticut 06095 Gentlemen:

This refers to the QA Program Inspection conducted by Mr. D. G. Anderson of this office on flovember 13-17, 1978, of your facility at Windsor, i

Connecticut, and to the discussions of our findings with Mr. C. W. Hoffman and members of your staff at the conclusion of the inspection.

Areas examined during the QA Program inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures anc representative records, interviews with personnel, and observations by the inspector.

During this inspection it was found that the implementation of your Quality Assurance Program failed to meet certain NRC requirements. The specific findings and references to the pertinent requirements are ihntified in the enclosures to this letter.

Please provide us within thirty (30) days a written statemer.L containing, (1) a description of any steps that have been or will be taken to correct this item, (2) a description of any steps that have been or will be taken to prevent recurrence, and (3) the dates your correct ~ve actions and preventive meosures were or will be completed.

In accordance with Section 2.790 of the Commission's " Rules of Practice,"

Part 2, Title 10, Code of Federal Reaulations, a copy of this letter and your reply together with the encloseo inspection report will be placed in the Commission's Public Document Room.

If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document.

If we do not hear from you in this regard within the specified period, the report will be placed in the Public Cocument Room.

790118 D M

Combustion Engineering, Inc. Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely, i

t

(' ',

,'3 Uldis Potapovs, Chief Vendor Inspection Branch

Enclosures:

1.

tiotice of Deviation 2.

Inspection Report No. 99900401/78-04

.