7/- cj7gg
! lF N $.~ M.</~
w,,
- p;3,
ARC PUBtA. ')CUMENT ROOM)
Department of Energy Washington, D.C. 20545 g
DEC1 1978 d
NR:RR:Lh!Wissel G#6156 11anager, Pittsburgh Naval Reactors Office S2W/S2Wa REACTOR SERVICING - SPENT CORE CARTRIDGE SHIPPING CONTAINER CEDTIFICATE OF'COMTLIA"CE; FORWARDING OF j'e Naval Reactors has reviewed the Bettis Safety Analysis if
'~~
Report for shipping irradiated S1W core cartridges in the S2W/S2Wa Spent Core Cartridge Shipping Container and f
concurs with the conclusjon that shipment of Core S1W-3F from USS SEAWOLF (SSN 575) in this container after December 12, 1978 (175 days after shutdown) complies with Title 10, Part 71 Code of Federal Regulations safety criteria.
l l
Accordingly, Naval Reactors has issued Certificate of Compliance USA /9785/BLF (DOE-NR) for shipment of Core S1W-3F in the S2W/S2Wa Spent Core Cartridge Shipping Container.
This Certificate is forwarded for use as the Enclosure to this memorandum.
The action taken by this memorandum is considered by
'the government to be within the contractual scope of the applicable prime contract and does not author)-i.e any delay in delivery or additional cost to the geivern-ment, either direct or indirect.
R. S. BRODSKY l
Division of Naval Reactors l
~~
Enclosure:
Department of Energy Certificate of Compliance USA /9785/DLF a
ge PNRO (2)
General !!anager, Bettis (w/o Enclosure)
M,,
h!anager, OPLT, Bettis MG3 hianager, OPLT - Refueling, Bettis O. R. Rieley, Bettis D. A. Nussbaumer, NRC,
C. E. h!acDonald, FCTR, NRC Dr. W. E. 1!ott, ECT, DOE 79010.2 03o7 _.
~
r,orm DCE aie U. 8. Departiment of Energy CamTIFICATE OF COMPLIANCE
- (g7 7 For Radioective Meterials Packeges gno49 ggg3 le. Certificato Nurrber 1b. Revision No.
Ic. Packege identification No.
Id. Page No.
le. Total No. Pegos.
USA /9785/BLF(DOE-NR)
Original USA /9785/BLF (DOS-NR) 1 h
- 2. PREAMBLE 2a.
Thre cartificate is leeumi to settsfy Sections 173.393a.173.394,173.305.end 173.396 of the Deportrnent of Transportation Homerdous y
Meteriale 9egulations (49 CFR 170-189 and 14 CF R 103) and Sections 146-10-10s and 146-19100 of the oopertrnent of Trenoportation g
Dangerous Cargoes Reguistions (46 CF R 146-149), as amended.
The packaging end contente deecribed in leem 5 below, eneets the oefety standards set forth in S@ pert C of Title 10, Code of Federal
['
2b.
Regutettons. Pert 71,"Packsging of Radioactive Meterial for Transport and Transportetton of Radioactive Meterial Under Corteln Conditions."
This certificate dove not relieve the consignor from compilence w6th any requirernent of the regu!stions of the U.S. Department of.
2c.
Transportation or other appiicable regulatory agencies, including the governrrent of any country through or into which the sack o9e will be trensported.
- 3. This -srtificate Is issued on the bests raf a eefety emelysis report of the pockege design or spotication-
~~
(11 Propered by (Name end addressJ:
(2) Titte end Identification of report or application:
(3) Date:
pgs.
Bettis Atomic Power Inboratory Safety Analysis Report for Packaging Post Office Box 79 for the S2W/S2Wa Spent Core Cartridge Shipping West Hifflin, PA 15122 Container Attention:
Mgr., OPLT - Reactor Servicing-SCA (See listing, pages 3 and 4)
- 4. CONDITIONS This certifieste is conditional upon the fulfilllw of the requi, err.ents of Subpert D of 10 CPM 71, es applicable, and the con.9tions specified in item 6 below.
- 5. Det:ription of Packagirg and Authorized Contents, Model Number, Fitsite Ctees, other Conditione.end Atforences:
a.
Description of Packasting -
Title:
S2W/S2Wa Spent Core Cartridge Shipping Container A Removal and Shipping (ISS) Container, a Shipping Shield, a Shipping Shield Cover with an integral energy absorption structure and penetration protection plate, a redwood energy absorber, two shipping shield cover shear plates, a control rod holddown plate, four lateral support devices, and a rail car comorisethemajorshippingequipmentneededforthetransportoftheS2W/82Wa spent cartridge.
PAS Costniner - This container is the primary containment vessel which holds the s7/ent core cartridge during transport and is basically a cylindrical shell having an inside opening of approximately 50 inches with one end of the container closed by an 8 inch thick, flat door that is hinged to a door frame. Four bolts and two cables for securing the door and opening or closing it are housed within six tubes that are attached to the outside diameter of tht shell. Tne barrel of c
the container is a velded, stainless steel cylinder, 2 inches thick, and approximately 12 feet long. Stainless steel flenges, 60 inches in diameter, 2 inches thick, are velded to the top and bottom ends of the barrel. The bottom
/
.tvo-thirds of the container is shielded with lead that is 812 inches thick for a height of 6 feet; the lead thickness then reduces over a height of 1 foot 10 inches to a thickness of 1 inch, with the 1 inch thickness extending up for six more inches.
es. Date of lieuence:
December 1, 1978 eb. Esoiretto cate: NONE POR THE U.8. ALRAMM 7 MG 7s. Address (of DOE 'Issura, orrie,J 7b. sigaetu e.Nerne,and Titre (of DOE Acaroving officInti
~
([ h, Division of Naval Reactors Department of Energy Washington, D. C. 20545 W. Wegne Deputy Director Divh:frin of Naval Rearators
4 Certificate of Compliance USA /9785/BIF (DOE-NR)
Four equally spaced support shoe housings are located approximately 91/2 feet above the bottom of the container. An empty container (without cover) veighs approximately 84,200 pounds.
..g.
5 The open end of the MS Container is closed with a 3 inch thick, 60 inch diameter, R
flat lov alloy steel plate that is mechanically fastened with twenty 11/4 inch diameter bolts to the top flange. Four 2 1/4 inch diameter, 28 inches long, stainless steel holddown stude are threaded through bosses in the cover and are The cover used to engage the flange of the depleted core during transport.
veighs approximately 2,100 pounds.
I Control Rod Holddown Plate - The holddown plate is a flat circular plate of
~
stainless steel construction, 48 inches in diameter and 4 inches thick, and is secured to the spent cartridge lifting lugs. Openings in the plate are provided for securing stainless steel rod holddown sleeves that are slipped over the control rod scram shafts for restrainths the control rods. The rod holddown plate weighs approximately 1,740 pounds.
hipping Shield - This outer container is a cast carbon steel shell with It is essentially circular a mounting ring velded to the.outside of the shell.
in shape but with three flat cides. The bottom of the container is 101/4 inches thick and the vall thichness varies from 10 inches at the bottom tapering to 21/2 inches at the top. A 11/4 inch thick flange, faced with 1/2 inch thick stainless steel, is located at the top opening. Access openings for visual inspections, temperature and cooling system equipnent are provided in the vall of the container. 'Ibe Shipping Shield which wei he 117,500 pounds is bolte'd S
to a well-type railroad car.
l Shipping Shield Cover - The cover assembly is a medium strength carbon steel veldment with a hic la ctrength steel plate bolted to the top aurface. This unit weighs approximately 20,900 pounds. The cover consists of a 73 inch outside diameter, 21/2 inch thick cylinder, 8 inches long, velded on one end to a 3 inch thick, 73 inch diameter top plate and on the other end to a 21/2 inch thick plate flange having eight straight edges along the outer Four 1 inch thick cylindrical skirts are velded to the undefaurface periphery.
of the top plate.
A 31/4 inch thick, 60 inch diameter, high strength steel plate is mechanically An energy absorbing structure, con-
- fastened to the top plate of the cover.
sisting of inclined inner and outer plates separated by webs, rings the Gusset shipping shield cover and is velded to the surface of the cover flange.
plates are velded to the cover noner.oly to further anchor the energy absorbing stnicture.
.6 w
Certir en e o emp an USA /9785/B1F (DOE-NR) 4 The
. The redwood energy absorber is attached to the shipping shield cover.
redwood energy absorber weighs about 2,400 pounds and consists of a telescoping Two shear plates attached between the steel assembly filled with redwood.
shipping shield cover flange and the shipping shield flange with 80 bolts-increase the strength of the joint.
d Lateral Support Devices - There are four lateral support devices placed within the B&S Container after it has been loaded for provjding lateral p{
Each device consists of a
support of the core cartridge during transport.
p t"o lateral support plates and two rotating rods, a locking plate and two locking rods, e,d a vertical support plate, with these components manufactured s
Th'e combined veight of the four from stainless steel and Inconel materials.
devices is approximately 450 pounds and the asse:nbled length is approximately nreaded. holes for the locking rods and unthreaded holes for the e
85 inches.
r rotating rods are provided in the vertical support plate (3" x 4" x 10") which Y~.
rests on the core cartridge flange. The rods extend through these boles and
~
~~
are attached to the locking plate and lateral support plates which are potiitioned over the support plate / divider plate joint of the core cartridge.
Refer to NAVSHIPS 0989-034-0000 and Westinghouse Electric Drawing 905E282 for additional description of the packaging.
b.
Authorized Contents The contents ef the container consist of one S1W Type 3 rodded, spent core cartridge, as described on Westinghouse Electric Drawing 923J619, contaminated with Transport Groups I, II, III, and IV materials.
c.
Restrictions.
p Shipments shall be made as Large Quani.ity Radioactive Material, Fissile 1.
Class III.
Shipment of S1W Core 3F chall not be made until 175 days after final 2.
shutdown of core (December 12, 1978 shipment allowable based on final shutdown date of June 20, 1978).
d.
References 1.
Container Technical Manual, NAVSHIPS 0989-034-0000,S2W/S2WaSpent Core Removal and Shipping Equipnent I
General Assembly - Spent Core Shipping Container, Westinghouse Electric 2.
Drawing 905E282 Core Cartridge Assembly, Westinghouse Electric Drawina 923J619 3
3 (2) and 3 (3)
Supporting data which shows the shipping equipnent provides adequate protection j
under both normal transport and accident conditions is contained in the w
e 9
Cert,1ficate of Compliance USA /9785/BIE (DOE-NR) following documents:
WAPD-OP(R)C433datedJuly 22, 1975 c.g WAPD-OP(R)C464 dated November 21, 1975 we
'l WAPD-OP(R)C491 dated February 20, 1976 n
E WAPD-OP(R)C-746 dated April 14, 1978 WAPD-OP(R)C-810 dated September 14, 1978 7
WAPD-OP(R)C-818 dated September 28, 1978 WAPD-OP(R)C-826 dated October 23, 1978 WAPD-OP(R)C-828 dated November 2,1978 WAPD-OP(R)C 833 dated November 20, 1978 O
4 so.
- "'+**9e=Dm +f"
--g,%
O