Forwards Insp Rept 50-289/71-06.No Noncompliance Noted. Potential of Serious Fire Noted in Ring Girder Repair Area. Damage Could Result to Concrete,Reinforcing Steel & Tendon Sheathing in Area
ML19262A456
Person / Time
Site: Crane 
Issue date: 12/07/1971
From: Howard E
US ATOMIC ENERGY COMMISSION (AEC)
To: Henderson J
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML19262A457 List:
References
NUDOCS 7910290801
Download: ML19262A456 (1)


Text

-

.r...*

P-'

UNITED STATES ATOMIC ENERGY COMMISSION.

S/

/ V\\

OlVISION OF COMPLIANCE 201 645. 3942

  • {

N l8)

REGION I 4

5 7 970 EnOAD STnZET sf p*

NEWARK NEW JERSEY 07102 December 7, 1971

[

m J~. ' B. Henderson,. Chief, Keactor Construction r '.

~'

Branch, Division of Compliance, HQ METROPOLITAN EDIS0Zi COMPANY, THREE MILE ISLAND 1

~

CO REPORT No. 50-289/71-06 The subject inspection report is forwarded for information.

No items of nonconformance were identified during this inspection; however, a potential for a serious fire was noted in the ring girder investigation / repair area. Widespread damage to concrete, reinforc-ing steel and tendon sheathing could result from the hazardous con-ditions in this area. This falls in the category of industrial safety and does not constitute an item normally under our jurisdic-tion.

1, 9m t U E. M. Howard Senior Reactor Inspector

Enclosure:

Subject Inspection Report cc:

E. G. Case, DRS (3)

R. S. Boyd, DRL (2)

R. C. DcYoung, DRL (2)

D. J. Skovholt, DRL (3)

H. R. Denton, DRL (2)

A. Giambusso, CO 1480 356 R. H. Engelken, CO L. Kornb lith, Jr., CO Regicnal Directors, C0 DR Central Files [

f O/

7910290