ML19262A303

From kanterella
Jump to navigation Jump to search
Action Control Form CDR 253 Re Request for Evaluation of Technical Adequacy of Corrective Action & Final Resolution of Deficiency Discovered in Sodium Thiosulfate Tank Per Jg Miller to DF Knuth
ML19262A303
Person / Time
Site: Crane Constellation icon.png
Issue date: 04/17/1974
From: Jennifer Davis
US ATOMIC ENERGY COMMISSION (AEC)
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19262A299 List:
References
CDR-253, NUDOCS 7910260631
Download: ML19262A303 (1)


Text

-

To:

J. P. O';

lly, R0:I

~

~

FSI.En ACTION CC!720L FOS!

A.

Action Code CDR#253 Name of Licensee and Facility Metropolitan Edison Co. (Three Mile Island li Docket No. or License No.

50-289 Title CDR Evaluation and Followuo CDR Date Rec'd 4/16/74 Origin B.

FS&E3 3 ranch Coordinator:

Bryan Drcher X

G. Gower Ellia

.Paulus H. D. Thornburg Complet, ion Requested by C.

Action Requested of:

ADREMP M&?POS EPB RPS ADC0 OB CB TAB 00E Region I kcutine Date Requested 4/17/74 Completion Requested by Reference Letter dated April 11, 1974 to D. F. Knuth from Mr. J. G. Miller.

D.

Action Requested The Metropolitan Edison Company (Three Mile Island Unit 1) covering the sodium thiosulfate tank failure is being assigned to Region I for evaluation of the technical adequacy of the corrective action and the final resolution of the deficiency.

E.

Date Action Ceepleted Close-out (Date & Method)

Cor:ments : If cocpletion date is not consistent with your work schedule, please let us know.

fc,9 J. G. Davis, Deputy Director for Field Operations Directorate of Regulatory Operaticr-N

/

O P

7910280 63/

~

~

1485 007