NRC iTRIBUTION FOR PART 50 DOCK' M ATE RI AL (TEMPORARY FORM)

CONTROL NO:4940 FILE:

FROM: s troplican Edison Co.

DATE OF DOC DATE REC'D LTR TWX RPT OTHER Reading, Pa

/

/

R.C. Aracia

/ 2 f/ 7 5-5-75 xn TO:

ORIG CC OTHER SENT AEC PDR vvv-Mr. R.L. Spessard 1-signed SENT l.OCAL PDR xxx CLASS UNCLASS PROPINFO INPUT NO CYS REC'D DOCKET NO:

xxxx 1

50-289 DESCRIPTION:

ENCLOSURES:

Ltr refAbnormal occurrence #75-07 furn inspection results concerning motor control center units......

PLANT NAME: Three Mile Island #1 FOR ACTION / INFORM

  • TION 5-9-75 JG3 A

BUTLER (L)

SCHWENCE (L) ZIEMANN (L)

REG AN (E)

W/ Copies W/ Copies W/ Copies AW Copies CLARK (L)

STOLZ (L)

DICKER (E) 4.E,1R (L)

W/ Copies W/ Copics W/ Copies WDCocies PARR (11 V ASSALLO (L)

VM!GHTON(E)

?PEIS W/ Copies W/ Copics W/ Copies W/ Copies KNIEL (L)

PURPLE (L)

YOUNGBLOOD (E)

LICENSING PROJECT MANAGER W/ Copies W/ Copies W/ Copies W/ Copies s

INTERNAL DISTRIBUTION

~,F Tf,CH REVIEW DENTON LIC ASST.

A/T IN D v rw PO R "TCHROEDER

/A'lM ES R. DIGGS (L)

BR AITM AN OGC, ROOM P E06A. *.TACCARY GAMMILL H. GE ARIN (L)

SA LTZM AN GSeSICK/STAF F KNIGHT KASTNER E. GOULBOURNE (L)

ME LTZ

  • CASE DAWLICKl BALLARD P. KREUTZER (E)

GI AM BUSSO SHAO SPANG LE R J. LEE (L)

_P_L ANS BOYD g ELLO M. MAIGRET (L)

MCDONALD MOORE (L)

.At'OUSTON ENVIRO S.REEDtL, CHAPMAN DEYOUNG (L) 40VAK MULLER M. SERVICE (L)

DUBE (L r; SKOVHOLT (L)

SS DICKER S. SHEPPARD (L)

E. COUPE GOLLER (L) (Ltr)

PO LITO KNIGHTON M. SLATER (E)

PETERSON P. CO LLINS

.YfDESCO YOUNG B LOOD H

M!TH (L)

.,#ARTFIE LD (2)

DE. ' SE J. c0LLINS REGAN TE ETS (L)

KLECKER G OPR LAIN AS PROJECT LDR

. WILLI AMS (E)

EISENHUT E & REGION (2)

BE3.AROYA V. WILSON (L) glGGINTON p!PIC3 T* M OE

.#tTL LME R HAR LESS R. INGRAM (L)

STEELE M AN4u 8M.

EXTERNAL CISTRIBUTION

.c A

M LOCALPDR Harrisburg, Pa

  1. TIC (ASERN ATHY) (1)(2)(10) - N ATION AL LASS 1 - PDR SAN /LA'NY

,,, P'- NSIC (S UCH AN AN) 1 - W. PENNINGTON, am E-201 GT 1 - BROOKH AVEN NAT LAS 1 - ASLB 1 - CONSU LTANTS 1 - G. U LRI KSON, O R.N L 1 - Newton Ardarson N EWM AR K/8 LUM E/AG B ABI AN 1 - AGMED (RUTH GL'SS?.lAN)

  1. [ - ACRS NENT Rm B.127 GT '

+o l a yt.r ni.

82 257

' ~ $r ~ " " " * ' ' ' ' " '" " ~ ' '

3 79102605 5 7

/ W " ? nf J

Z O h.n,. +.x,n, wg na METRODOLITAN EDISON COMPANY ec-cc :cE acx 54:

=E Acit.c. PI.Nsytv Ant A 10:c:

Tstsswc se :15 - 9:9 ca:

G@ 0985 A?R L

,'.75 Mr. R. L. Spessard Office of Inspection & Enforcement - Regien 1 U. S. Nuclear Regulatory Cc==lssion 631 Park Avenue King of Prussia, Pennsylvania 19hc6

Dear Mr. Spessard:

In cecordance with your agreement with cur J. G. Herbein, we are prcviding a report of the inspecticn of safety-related =cter control center units as described in Abner =al Occurrence Report 50-289/75-07 at our Three Mile Island nuclear Station Unit 1 (TMI-1).

A total of 12h safety-related =oter control units have been inspected.

Of these, h6 units were fcund to have deficiencies.

(These deficiencies were si=ilar to those described in the referenced report.) The deficiencies have been corrected on kl units, verk is in process on one unit, and we are avaiting =aterial for correction of four units. Ncne of the deficiencies fcund veuld have adversely affected the operability cf the motor control center units or associated ec=penents.

Should ycu require additional information, full documentation is availcble at the TMI-l site.

Sincerely, 1 b5

. C.

.old Vice President.

RCA:ESB:eg File 7.7.3.5.1/20.1.1 lj % 1,.

1482 258