ML19261F045
| ML19261F045 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 07/11/1972 |
| From: | Maccary R US ATOMIC ENERGY COMMISSION (AEC) |
| To: | Deyoung R US ATOMIC ENERGY COMMISSION (AEC) |
| References | |
| NUDOCS 7910180662 | |
| Download: ML19261F045 (1) | |
Text
D Y RI b IID N N
bd
\\
- a J'JL 111371 1
R. C. DeYoung, Assistant Director for PWRs Directorate of Licensing THREE MILE ISLAND NUCLEAR STATION, UNIT 1 (OL) TECHNICAL SPECIFICATION REVIEW The Three Mile Island 1 Technical Specifications, dated April 1972, have been reviewed by tne Materials Engineering Branch, L.
Our sections of the Technical Specification review are enclosed.
R. R. Eaccary, Assistant Director for Engineering Directorate of Licensing Enclosures Materia).s Engineering Bra.2ch Review of Technical Specifications a.
Plant Names Three Mile Island 1 b.
Licensing Stage OL c.
Docket No.: 50-289 d.
Responsible Branch and Project Leader: PWRf26 H. E. Schierling e.
Requested Completion Date: July 15, 1972 f.
Next Planned Action: None g.
Description of Response Technical Specification Review h.
Review Status: Complete pf cc w/ enc 1:
cc w/o enc 1:
S. H. Hanauer, DRTA A. Giambusso, L v
i J. M. Hendrie L W. G. Mcdonald, L S. S. Pawlicki, L K. Kniel, L
/
H. E. Schierling, L
- p M. B. Fairtile, L C
Docket File (50-289)
L R/T MTEB R/F RMGustafson, '
1486 150 omcE > 1:HTEB
.L:XTE.B II -
SURNAME >.M[girtI Ie /g...SSPawlicki RRMaccary.....
l7/
-. -. f.../72 7/g/72 7/11/72 DATE >
Form AEC-Hs iRev. 9-53) AEC'4 0240
.,. s. covrasurNT PM:NT*N3 OFFICr : 15'3 0 - 405 346 2910180662 jg