UNITED STATES ATOMIC ENERGY COMMISSION

~

DIVISION OF COMPLIANCE 201 64s. 3942,f l* 1 REGION I

,' ~

l *I

/

970 BROAD STREET 2O 3 NEWARK. NEW JERSEY 07ttTF's -

a

+

s

-R:::21:P"N

~

j l.T.'

\\

= - -

April 16,' Q J. P. O'Reilly, Chief, Reactor Inspection and Enforcement Branen, Division of Compliance, HQ INQUIRY MEMORANDUM METROPOLITAN EDISON COMPANY (TMI-1) 289/70-A DECAY HEAT COOLERS Region I was provided the following information on April 16, 1970.

During a vendor inspection, the licensee determined that the decay heat cooler tubes (S/S) were cleaned in a chlorinated solvent (Trade-name - Valcolene). The coolers have been installed at the site.

B&W has authorized the removal and return of the coolers to the manu-facturer: Whitlock Manufacturing Company,101 South Street, West Hartford, Connecticut.

A chemical analysis of the solvent (Valcolene) showed that it con-tained 37. methyl chloride.

N. C. Moseley Senior Reactor Inspector-cc:

E. G. Case, DRS u RL_(2 R. S d oyd D

S. Levine, DRL D. J. Skovholt, DRL (

L. Kornblith, Jr., C0 REG files Regional Directors, CO 1483 271 I

7910170 9f>7 P