Text

.

License No. DPR-50

,P APPENDIX A NOTICE OF VIOLATION Based on the results of the NRC inspection conducted on November 16-19, 1976, it appears that certain of your activities were not conducted in full compliance with conditions of your NRC License No. DPR-50 as indicated

~

below.

Items A and B are infractions and Item C is a deficiency.

A.

10 CFR 20.203(b) " Caution signs, labels, signals and controls" requires that such radiation area be conspicuously posted with a sign or signs bearing the radiation caution symbol and the words " CAUTION RADIATION AREA."

Contrary to this requirement, an area accessible to personnel in which a radiation level of 15 mrem /hr was measured near the precoat recirculation piping was not posted as a radiation area when inspected on November 16, 1976.

This item is recurrent in that similar items of noncompliance were brought to your attention in letters dated April 9, 1975, and August 2, 1976.

i B.

Technical Specification Section 6.11 requires adherence to procedures

-)

for all operations involving personnel radiation exposures, and Health. Physics Procedure 1749 requires quarterly calibrations of PAC-4S survey instruments, plus or minus li weeks.

g Contrary to the above, two PAC-4S survey instrunents were identified 3

on November 19, 1976, Serial Nos. 1357 and 2752, that were available for use and had not been calibrated since July 14, 1976, and were more than three weeks overdue for calibration.

This item is recurrent in that similar items of noncompliance were brought to your attention in letters dated April 20 and September 21, 1976.

C.

10 CFR 30.41(:c) " Transfer of byproduct material" requires that before transferring byproduct material the licensee transferring the material shall verify that the transferree's license authorizes the receipt of the type, form, and quantity of byproduct material to be transferred.

Contrary to this requirement, a pump was shipped on April 6, 1976, to a repair shop and the transferree's license did not authorize the receipt or possession of the byproduct materials present in the shipment.

1483 073 N.