Li PHILAD ELPHI A ELECTRIC COM PANY 2301 M ARKET STREET P O BOX 8699 PHILA DELPHI A. P A.19101 (215) e.*15 cot smstes t omtree,,
vic e peEsicE% f E.E : T R'C ** C C v C T,0%
June 22, 1979
.r.
Th oma s A.
Ippolito, Chief O p e r.i t i n g Reactors 3 ranch 3 Division of Operating Reactors U.S.
"RC
'J a s h i n g t o n, 7C 20555 Dear 'tr.
Ippolito:
Re:
Peach 'ottou Unit 3 Proposed Inspection rogran for Feedwater '?ozzles and Etodification Program for the C3D Return Line for Fall 1979 Refueling Outa3e This letter is in response to your letter to 'Ir.
E.
G.
Sauer, Jr. of ?ebruary 13, 1973, which requested that we provide our proposed feedvater nozzle inspection program for the 1979 refueling outage for Peach Botton Unit 3 ninety days prior to the start of the outa3e.
Feedwater Mozzle Program All feedwater nozzle safe ends, bores, and inside blend radii will be ultrasonically tested.
If any indication is found to be unacceptabla, the associated sparger will 5e recoved, a dye-penettsnt test will be performed and any u n a c c e p t a 'c l e dye-penetrant Indications will
'o e removed.
In adiition, a visual inspection of all feedwater spargers vill be performed.
The support for this conservative course of action is contained in
" Peach lotton Unit 3 Coc-3 Feedwater : o z e. l e Inspectic n Reconaendations", a copy of which is attached.
2311 110 C'7 7eturn Line Procram Our present plan for the Unit 3 CR0 return line nozzle is to cut and cap the CRJ return line and re-route the CRD return flow to the RUCU return to the feedwater inlet lines.
The re-routed v
0 7\\
\\
7 906260 3IV
(*
Ir.
T.
\\.
Ipoolito, Chit!
Page 2 CF3 return line wouli nor1 ally isolated using aanual valves which will be accessibla during power oueration.
Shouli y ou have any quentions or require any additional infornation, please contact us.
e r y truly yours, 7
C 'd 7'.,,rm Y. b D
Y, h d Q t
.\\ t t.1 c h m e n t 2311 111
.