Text
f/C DAIRYLAND POWEIt COOPEIRATIVE Ba Groue, Okonan 54601 April 20, 1979 In reply, please refer to LAC-6232 DOCKET NO. 50-409 Mr. James G. Keppler Regional Director U. S. Nuclear Regulatory Commission Directorate of Regulatory Operations Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137
SUBJECT:
DAIRYLAND POWER COOPERATIVE LA CROSSE BOILING WATER REACTOR (LACBWR)
PROVISIONAL OPERATING LICENSE NO. DPR-45 IE BULLETIN NO. 79 USE OF ASME SA-312 TYPE 304 STAINLESS STEEL AT LACBWR FACILITY
Reference:
(1)
NRC Letter, Keppler to Linder, dated March 12, 1979.
Dear Mr. Keppler:
This is in response to your letter (Reference 1) which contained IE Bulletin No. 79-03 requesting information regarding the use of ASME SA-312 Type 304 stainless steel piping at our facility.
The bulletin reported the discovery of defects in longitudinal welds in Class 2 pipe supplied by Youngstown Welding and Engineering Company of Youngstown, Ohio and requested that Dairyland Power Cooper-ative determine if such piping is in use or planned to be used at our facility.
Our plant piping was supplied in accordance with the design specifi-cations of Allis-Chalmers Spec. No.41-585 and Sargent and Lundy No. W-1789 which specify seamless A-376 for pressure systems above 150 lb. Class.
Seamless A-312 Type TP-304 pipe is also specified for systems up to 150 lb. Class.
It has further been determined by a review of our records that pipe manufactured by Youngstown Welding and Engineering Company is not in use nor is it planned for use in safety-related systems at the La Crosse Boiling Water Reactor facility.
In addition, welded seam 304-SS pipe is not planned to be used for Class I or Class II pipe at this facility.
2285 177
, 2 3 1979 7906020189
Mr. James G. Keppler LAC-6232 Regional Director April 20, 1979 If you have any questions, please contact us.
Very truly yours, DAIRYLAND POWER COOPERATIVE m /?4 tdb.
2 Wlt s '
Frank Linder, General Manager FL: CWA:af ac:
U.
S. Nuclear Regulatory Commission Office of Inspection and Enforcement Division of Reactor Construction Inspection Washington, D. C.
20555 2285 178