Responds to IE Bulletin 79-03.No Type 304 Stainless Steel Piping Mfg by Youngstwn Welding & Engineering Co Is in Use or Planned for Use in safety-related Sys at Facility
ML19261D308
Person / Time
Site: La Crosse File:Dairyland Power Cooperative icon.png
Issue date: 04/20/1979
From: Linder F
DAIRYLAND POWER COOPERATIVE
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
LAC-6232, NUDOCS 7906020189
Download: ML19261D308 (2)


Text

f/C DAIRYLAND POWEIt COOPEIRATIVE Ba Groue, Okonan 54601 April 20, 1979 In reply, please refer to LAC-6232 DOCKET NO. 50-409 Mr. James G. Keppler Regional Director U. S. Nuclear Regulatory Commission Directorate of Regulatory Operations Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137

SUBJECT:

DAIRYLAND POWER COOPERATIVE LA CROSSE BOILING WATER REACTOR (LACBWR)

PROVISIONAL OPERATING LICENSE NO. DPR-45 IE BULLETIN NO. 79 USE OF ASME SA-312 TYPE 304 STAINLESS STEEL AT LACBWR FACILITY

Reference:

(1)

NRC Letter, Keppler to Linder, dated March 12, 1979.

Dear Mr. Keppler:

This is in response to your letter (Reference 1) which contained IE Bulletin No. 79-03 requesting information regarding the use of ASME SA-312 Type 304 stainless steel piping at our facility.

The bulletin reported the discovery of defects in longitudinal welds in Class 2 pipe supplied by Youngstown Welding and Engineering Company of Youngstown, Ohio and requested that Dairyland Power Cooper-ative determine if such piping is in use or planned to be used at our facility.

Our plant piping was supplied in accordance with the design specifi-cations of Allis-Chalmers Spec. No.41-585 and Sargent and Lundy No. W-1789 which specify seamless A-376 for pressure systems above 150 lb. Class.

Seamless A-312 Type TP-304 pipe is also specified for systems up to 150 lb. Class.

It has further been determined by a review of our records that pipe manufactured by Youngstown Welding and Engineering Company is not in use nor is it planned for use in safety-related systems at the La Crosse Boiling Water Reactor facility.

In addition, welded seam 304-SS pipe is not planned to be used for Class I or Class II pipe at this facility.

2285 177

, 2 3 1979 7906020189

Mr. James G. Keppler LAC-6232 Regional Director April 20, 1979 If you have any questions, please contact us.

Very truly yours, DAIRYLAND POWER COOPERATIVE m /?4 tdb.

2 Wlt s '

Frank Linder, General Manager FL: CWA:af ac:

U.

S. Nuclear Regulatory Commission Office of Inspection and Enforcement Division of Reactor Construction Inspection Washington, D. C.

20555 2285 178