2

~

4 r

Form P RC 618 U.S. NUCLE AR REGULATORY COMM!SSION 4

CERTIFICATE OF COMPLIANCE to CFR 71 For Radioactive Materials Packages 1.t a l Certificate Number 1.(b) Revision No.

1.(c) Packace identification No.

1.(d ) Pages No. 1.(e) Tctal No. Pages 6206 2

USA /6206/AF 1

2

2. PRE AMB LE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.26 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Ccoartment of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amenced.

2.(b)

The packaging and contents described in item 5 below, meets the safety sttndards set forth in Subpart C of Title 10, Code of Federal Regulatnns, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radiontive Material Under Certain Conditions /

2.(c)

This certificate does not relieve the consignor from compliance with ary requirement of the regulations of the U.S. Depar ment of Transportation or other applicable regulatory agencies, including the government of any country through or into wf ich the package wll be transported.

3. Thi? certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

The Babcock & Wilcox Company The Babcock & Wilcox Company application dated P. O. Box 1260 January 16, 1970, as supplemented.

Lynchburg, VA 24505 3.(c)

Docket No.

7].62C6 4.

CONDIT.ONS This certificate is conditional upon the fulfilling of the requirements of Subrart O of 10 CFR 71, as applicaole, and the conditions specified in item 5 below.

5. Description of Packagirr. and Authorized Contents. ' iodel Number, Fissile Class. Other Conditions, and

References:

(a) Packaging (1) Model No.:

Model B (2) Description A full assembly shipping container consisting of a steel strong-back, clamping assembly, shock mounted to a steel outer container.

Two 3/16-inch thick, 8-5/8 inches high and full length stainless steel plates containing 1.5% minimum boron are positioned between adjacent fuel assemblies. The outer container is approximately 40-inches diameter by 200-inches long.

(3) Drawings The container is constructed in accordance with The Babcock &

Wilcox Company Drawings Nos. PE-52F, Revision 0; PE-53F, Revision 0; and PE-54F, Revision 0.

790427005(

t Page 2 - Certificate No. 6206 - Revision No. 2 - Docket No. 71-6206 5.

(b) Contents (1) Type and form of material UO sintered pellet diameter 0.30 inch to 0.60 inch.

2 Uranium may be enriched to a maximum 4.05 w/o in the U-235 isotope. The pellets are clad in minimum 0.020-inch thickness zircalloy or minimum 0.016-inch thickness stainless steel rods. The rods are assembled into fuel assemblies with a maximum cross section of 8.6-inch by 8.6-inches. The void volume within the fuel assembly shall not exceed two (2) times the volume of UO2 in the fuel assembly.

(2) Maximum quantity of material per package Two (2) tuel assemblies containing not more than 18.8 kg U-235 per assembly.

(c) Fissile Class III Maximum number of packages per shipment Twenty (20) 6.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR s71.12(b).

7.

Expiration date: January 31, 1980.

REFERENCES The Babcock & Wilcox Company applicaticn dated January 16, 1970.

Supplements dated:

March 3,1970; November 25, 1974; and March 21, 1979.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION k

Cnarles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety Date:

.