Requests Revision of Certificate of Compliance 5908 to Allow Shipment of Increased Limits of U-233 in DOT-GM Containers
ML19261C982
Person / Time
Site: 07105908
Issue date: 03/28/1979
From: Brodsky R
ENERGY, DEPT. OF
To: Nussbaumer D
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
Shared Package
ML19261C983 List:
References
NR:DRS:DLA1F-Z#, NUDOCS 7904230091
Download: ML19261C982 (2)


Text

-., p; ex *pgt{T ROOW.

%/

.w p-Department of Energy itJjt;DRS:DLAlf Z#754 Washington, D.C. 20545 F.i lif4 arch 28, 1979 D. A. flussbaumer Assistant Director for flaterial 3

7

+ / / (/

Safety & Licensing 7/-U(/MO U.S. fluclear Regulatory Conmission Washington, D.C. 20555 i

THRU:

Dr. W. E. flott, Director Environmental Control Technology Department of Energy REVISION OF flVCLFAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR DOT-6M SHIPPIflG CONTAINER; REQUEST FCR The fluclear Regulatory Coimiission (fiRC) Certificate of Compliance USA /

5908/B( )F contains provisions for shipping U233 in DOT-6M shipping containers. The Gattis Atomic Power Labcratory. DOE, is a registered user of this certificate and has been utilizing it to ship L!-lBR fuel fabrication wastes.

Bettis has identified the following concerns with the existing Certificate of Compliance:

1.

The shipment of U233 mixtures is limited to UO -Th0p with a nominal 2

U232 contamination of 10 ppm.

Specifying a limit on the U232 con-tamination and the type of U233 mixtures shipped are not necessary for nuclear safety and, therefore, should not be included in the certificate.

r UO2 binary) wastes, 2.

The safety analysis for shipping U233 (Ub2 i.e., Bettis letter WAPD-RS(CC)-620 dated May 8,1973 (attached as enclosure 1), was performed solely for 55 gallon 6M drums.

Since the certificate limits the maximum fissile content, larger 6M drums with this same loading will be less reactive and therefore acceptable for shipment.

fio such argument is readily available for smaller drums; therefore, the certificate should specify a minimum drum size.

On the basis of the above, f4RC is requested to revise certificate of compliance USA /5908/B( )F as follows:

1.

Change paragraph 5(b)(1)(ii) to read "UO2 or UO2 mixtures in the form of powder or compact pellets."

J, 2J:'GGD 790ddacow

D. A. Nussbaumer, NRC 2

ilR:DRS:DLAlf Z#754 2.

Add the sentence "The package size shall not be less than 55 gallons."

to paragraph 5(b)(2)(iii).

..jfL k, R. S. BRODSKY I

Division of Naval Reactors Enclosure (1):

Bettis letter WAPD-RS(t ')-620 dated May 8,1973 4

Copy to:

D. A. Nussbaumer, NRC C. E. MacDonald, NRC (w/e)