NWI DOCUMENT QA-NRC7068-PTRM

, ',,, \\2 00

\\

Quality Assurance Program for:

Packaging of Radioactive material for transport and transportation of radioactive material under certain conditions" as required by 10 CFR 71.61 Nuclear Welding, Inc.

8600 Joliet Road McCook, Illinois 60525 7 9 04 0 2 014q

NW1 DOCUMENT QA-NRC7068-PTRM For Packaging and Transportation of Radioactive Material, O Revision, June 24,1978 Table of Contents SeClion Master Revision Log a

Scope 1

Quality Assurance Criteria for Receiving Radioactive Material Packages 2

Quality Assurance Criteria for Shipping Packages of Radioactive Material 3

Receival of Damaged Shipping Packages 4

Document Control 5

Audits 6

Receiving of Radioactive Materials aa Shipping of Radioactive Materials bb Shipper's Certification for Materials Classified as Radioactive Material cc

NW1 DOCUMENT O A NRC7068 PTRM For Packaging and Transportation of Radioactive Material, O Revision, June 24,1978 This title page is a record of all revisions to this specification. Each time this specification is revised, new pages are issued. Holders of this specification are to retain only the latest issues in their active files, revision date section QA Mgr. spprovst abstreet of revision

NW1 DOCUMENT QA NRC7068-PTRM For Packaging and Transportation of Radioactive Material, O Revision, June 24,1978 m

1.0 Scope 1.1 This Quality Assurance program is established to ensure adequate and proper control over the shipment and receiving of Radioactive materials in their shipping packages.

1.2 It is not our objective to manufacture, repair, modify, etc. any shipping packages. We will only use shipping packages (which have been approved by the N.R.C.) as supplied by the manufacturer of the source or source exposer division.

NW1 DOCUMENT OA NRC7068-PTRM For Packaging and Transportation of Radioactive Material, O Revision, June 24,1978 2.0 Quality Assurance Criteria for Receiving Radioactive Material Packago 2.1 When packaged radioactive materials are received by NWI, the following procedure is to be observed to ensure a safe and adequate plan of receival.

2.2 Procedure for Receiving Packages of Licensed Material 2.2.1 Arrange to receive notification from the carrier, of the arrival of the package, at the time of arrival.

2.2.2 Radioactive material shall be picked up from the carrier terminal expeditiously upon receipt of notification, from the carrier on its arrival.

2.2.3 A visual inspection of the shipping package shall be made and recorded on Form NWl-1.

(See Exhibit 1) 2.2.4 As soon as practical, but no longer than three hours upon receipt of radioactive material, the external surfaces of the package shall be monitored, and recorded on Form NWl-1 along with the date, source model and serial numbers, time of notification, time of pick-up, etc., shall be recorded.

2.2.5 Any radioactive material found to be in excess of that required in Part 20.205, shall be immediately reported to the appropriate NRC regional office.

NW1 DOCUMENT OA NRC7068-PTRM For Packaging and Transportation of Radioactive Material, O Revision, June 24,1978 3.0 Quality Assurance Criteria for Shipping Packages of Radioactive Material 3.1 When packages of radioactive material are shipped by NW1 the following precedure is observed to ensure a safe and adequate plan of shipment.

3.2 Procedure for Shipping Packages of Radioactive Material 3.2.1 Notify source manufacturer to arrange receival of depleted or malfunctioning source.

3.2.1.1 Prior to shipping a visual inspection of the source container and shipping package shall be made. (See Form NWl.2, Exhibit 2) 3.2.1.2 No shipping will be permitted in a shipping package that is damaged, unsealed or unproperly marked with the required DOT labels.

3.2.2 Proper shipping certification forms that are supplied by the shipper, must be correctly completed. (See Form NWl-3, Exhibit 3)

NW1 DOCUMENT QA NRC7068-PTRM For Packaging and Transportation af Radioactive Material, O Revision, June 24,1978 a

4.0 Receival of Damaged Shipping Package 4.1 Upon receival of a damaged shipping package, the following procedures shall be imposed:

4.1.1 All unauthorized personnel shall be removed from the area; 4.1.2 Shipping package shall be monitored with a calibrated survey meter to ensure that the contents are still in a safe position within the source device; 4.1.3 The standard procedure for receiving packages of licensed material shall be followed. (See Section 2) 4.1.4 The source exposure devise shall be removed from the shipping package and monitored with a calibrated survey meter. At this time, the exposure device is visually inspected for damage.

4.1.5 Source manufacturer shall be notified as to the extent of damage and the required corrective action to be taken.

NW1 DOCUMENT QA NRC7068-PTRM For Packaging and Transportation of Radioactive Material, O Revision, June 24,1978 5.0 Document Control 5.1 All documentation on shipping and receiving of radioactive materials shall be controlled by the Radiation Safety Officer in a designated area for authorized personnel only.

NW1 DOCUMENT QA NRC7068-PTRM For Packaging and Transportation of Radioactive Material, O Revision, June 24,1978 6.0 Audits G.1 Audits will be performed on a quarterly basis.

6.2 Re-audits shall be performed whenever a deficiency is found.

NWI DOCUMENT OA NRC7068 PTRM For Packaging and Transportation of Radioactive Material, O Revision, June 24,1978 RECEIVING OF RADIOACTIVE MATERIALS NWi-1 date from shepser visual inspectian of shipping packeges any obvious damexp* to the outside of shipping packarp packs e properly sealeil MT latxIs properly af fims remar k s

~~

~

isotope number of curses

~

model number ser tal numtwr camera majel number serial numtwr time notifeed for pick up time of pick up transport group transport enden monitor extemal surface of package at 3 feet M H/hr.

surface readmg Received By title Exhibit 1

NW1 DOCUMENT QA-NRC7068-PTRM For Packaging and Trensportation of Radioactive Material, O Revision, June 24,1978 SHIPPING OF RADIOACTIVE MATERIALS NWi2 date shipper to frorn visualinspection of shipping package package properly sealexj DOT lat>els properly affixed remark s isotope number of curw*s model number serial number camera model number serial numtwr time shipped transport group monitor extemal surface of package at 3 feet M H/hr.

Shipped By titie RSO will make quarterly audit to assure procedure is followed.

Exhibit 2

NW1 DOCUMENT OA NRC7068 PTRM For Packaging and Transportation of Radioactive Material,0 Revision, June 24,1978 NW13 FIDERAL EXPRESS CORPORATION SHIPPER'S CERTIFICATION FOR MATERIALS CLASSIFIED AS RADIOACTIVE MATERIAL 1RANSI'OHI iHOPt fi SHIPI'1NG NAME RADIONUCLIDE FORM ACilVITY LAHEL INDEX Per Secton172 101. Ittle 49. Code of Name of gwvicipal OR OF g g gg3 F corral Hegulatons (49 CF R)

FLadioactive Nurnber Wiule i or MIGHT No obtweviatxwis permitted content Physat/

of Yellow 11 or f or Yellow tas Speofy each aricle separate y (49Cf R 173 3'O)

Chenucal Cunes Yellow ill Latw ts OrW appropnate) r Tius is to certdy that the atiove navned matenais are property clas9 feed descntef. pat,kageti marked, and labeled. and are o proper wrK1. tion for trangotiaton according to apphcarne regulations of the cairner arki Tetle 49. 04Kie of I ederal kegulatons if acceptarde for gassenger carrying aircraft ttus shiprnent is miended for use in. or walent to.

researth or medal d.agnosis or treatment itws contgqrc.ent is within the limitatons prescntet for (MARK ONE)

(

) HOIH PASSENGIR AND CARGO AlHCI(AFT

(

)CADGO ONLY AlHCILA)i NAME AND ADDRISS Of SHIPPIR NAME AND lif t L Of Pt RSOP! SIGNING CE HTifICA110N SIGN A1URL.

IMCRGE NCY f HONF NO

{

i DasTpunUTKw DAIL WMe - parbage Copy Canary - Cutlomet $eevery/M{ M FICSO49 (Hav 3/77) 8%* - Stas 4.or Copy Exhibit 3