ML19261C410
| ML19261C410 | |
| Person / Time | |
|---|---|
| Issue date: | 07/13/1978 |
| From: | Parr O Office of Nuclear Reactor Regulation |
| To: | Sherwood G GENERAL ELECTRIC CO. |
| Shared Package | |
| ML19261C400 | List: |
| References | |
| MFN-295-78, NUDOCS 7903220395 | |
| Download: ML19261C410 (1) | |
Text
( "'4,,
UNITED STATES
> *4 NUCLEAR REGULATORY COMMISSION E
E WASHINGTON. D. C. 20555 3{
E
%, +.. /
Central Files - Topical Reports JUL 131978 MFN 295-78 Genera! Electric Company cc:
L. S. Gifford ATTN:
Dr. G. G. Sherwood, Manager Safety and Licensing 175 Curtner Avenue San Jose, California 95114 Gentlemen:
SUBJECT:
REVIEW 0F GENERAL ELECTRIC TOPICAL REPORT NED0-10466,
" POWER GENERATION C0PTROL COMPLEX DESIGN CRITERIA AND SAFETY EVALUATION" We have completed our review of Revision 2 of the subject topical report.
Based on this review, we conclude that the report is acceptable for reference in license applications as specified in the enclosed evaluation.
The staff does not intend to repeat its review of this topical report when it appears as a reference in specific license applications, except to assure that the topical report is applicable to the specific plants involved.
abould regulatory criteria or regulat'ans change such that our cu...lusions concerning this topical report are invalida*ed, you will be notified and will be given the opportunity to revise and resubmit your topical report for review, should you so desire.
In accordance with established procedure, we request that General Electric issue a revised version of the subject topical report to include any suimementary information provided for our review of the report, this a:ceptance letter, 'and the enclosed staff evaluation.
Sincerely, ar'r ef Light Water Reactors Branch No. 3 Division of Project Management
Enclosure:
Topical Report Evaluation cc w/ enclosure:
Mr. L. Gifford General Electric Company 4720 Montgomery Lane Bethesda, Maryland 20014 7903220 3 95 Iit