Responds to 781227 Application to Ship Low Levels of Pu- Bearing Wastes in Super Tiger Packaging.Requests Info Demonstrating That Pu Is in Nonrespirable Form or That Inner Containers Will Maintain Integrity After Test
ML19261C102
Person / Time
Site: 07106400
Issue date: 02/26/1979
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Austin M
BABCOCK & WILCOX CO.
References
NUDOCS 7903140589
Download: ML19261C102 (2)


Text

1r

  • f"" " "'4 UNITED STATES e4 NUCLEAR REGULATORY COMMISSION

~*

h,k)k WASHINGTON, D. C. 20555

  • yp e

8 FEB 2 61979

%N+....o FCTR. RHO 71-6400 The Babcock & Wilcox Company ATTN: Mr. Michael A. Austin 609 North Warren Avenue Apollo, PA 15613 Gentlemen:

This is in regard to your application dated December 27, 1978 concerning the shipment of low levels of plutonium bearing wastes in the Model No.

Super Tiger packaging.

As noted in your December 27 letter, Revision No. 4 to the Certificate of Compliance (No. 6400) for the Super Tiger was issued to be consistent with the requirements of 10 CFR 571.42. We do not understand the basis for your statement that we either misinterpreted or based our judgement of the capabilities of the Super Tiger packaging upon an arbitrary assessment.

For your information, we are enclosing the Statement of Consideration (39 FR 20960) concerning 10 CFR 571.42 and the double containment requirement for plutonium that is in a respirable fonn.

The Commission concluded that the second (inner) barrier should maintain its integrity after the package was subjected to the normal and accident test conditions of transport.

We also note that the test results reported for the Super Tiger (second reference listed on Certificate of Compliance) indicate that the ir.ner 55-gal steel drums do not maintain their integrity when the package was subjected to the 30-foot free drop.

In connection with our review of your application, information should be provided which demon-strates that the plutonium is in a "nonrespirable" form or that the inner containers will maintain their integrity following the accident test conditions of transport.

7903.146 % 7

w w

The Babcock & Wilcox Company FEB 2 61979 Please advise us within thirty (30) days from the date of this letter when this information will be provided.

If you have any questions regarding this matter, we will be pleased to meet with you and your staff.

Sincerely, Char es E[. ! cDonald, Chief

/

Transportation Branch Division of Fuel Cycle and Material Safety

Enclosure:

As Stated

-