i e

q UNITED ST ATES j

5 NUCLE AR REGULATORY COMMISSION

[9{/L.

,1 g

REGION ill j ' g t

799 ROOSE VE LT ROAD r

GL E N E LL YN. IL UNots 60137 FEB 5

.379 State of Illinois Department of Public Health ATTN:

Mr. Gary N. Wright, Chief Division of Nuclear Safety 535 West Jefferson Street Springfield, IL 62761 Gentlemen:

The enclosed IE Information Notice No. 79-01 titled "Bergen-Paterson Hydraulic Shock and Sway Arrestors (HSSA)" was sent to the following licensees on February 2, 1979:

American Electric Power Service Corporation Indiana and Michigan Power Company D. C. Cook 1, 2 (50-315, 50-316)

Cincinnati Gas Electric Company Zimmer (50-358)

Cleveland Electric Illuminating Company Perry 1, 2 (50-440, 50-441)

Corconwealth Edison Company Braidwood 1, 2 (50-456, 50-457)

Byron 1, 2 (50-454, 50-455)

Dresden 1, 2, 3 (50-10, 50-237, 50-249; La Salle 1, 2 (50-373, 50-374)

Quad-Cities 1, 2 (50-254, 50-265)

Zion 1, 2 (50-295, 50-304)

Consumers Power Company Big Rock Point (50-155)

Midland 1, 2 (50-329, 50-330)

Palisades (50-255)

Dairyland Power Cooperative LACBWR (50-409)

Detroit Edison Company Fermi 2 (50-341) 79022802G8

State of Illinois ((g Illinois Power Company Clintoa 1, 2 (50-461, 50-462)

Iowa Electric Light & Power R:mpany Duane Arnold (50-331)

Northern Indiana Public Service Company Bailly (50-367)

Northern States Power Company Monticello (50-263)

Prairie Island 1, 2 (50-282, 50-306)

Tyrone Energy Park 1 (50-484)

Public Service of Indiana Marble Hill 1, 2 (50-546, 50-547)

Toledo Edison Company Davis-Besse 1 (50-346)

Union Electric Company Callaway 1, 2 (50-483, 50-486)

Wisconsin Electric Power Company Point Beach 1, 2 (50-266, 50-301)

Wisconsin Public Service Corporation Kewaunee (50-305)

Sincerely,

~

Gj: e d W-

? Helen Pappas, Chief Administrative Branch

Enclosures:

1.

IE Information Notice No. 79-01 2.

List of IE Information Notices Issued in 1979 cc w/encls:

Central Files Reproduction Unit NRC 20b PDR Local PDR NSIC TIC D. W. Kane, Sargent and Lundy

~

U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT REGION III February 2,1979 i

IE Information Notice Nc. 79-01 BERGEN-PATERSON HYDPMLIC SHOCK AND SWAY ARRESTORS (HSSA)

On December 4, 1978, Rancho Seco Nuclear Generating Station reported the failure of seven Bergen-Paterson HSSA (Snubber) units to lockup in the compression direction and the failure of one additional unit to lockup in the extension direction. These failures were identified during surveillance testing and the affected models included HSSA-3-6, HSSA-10-6 and HSSA-20-6. When the units were disassembled, the licensee observed damage to the poppet valve and seat on the compression side of the valve blocks of the seven units that failed in the compression direction.

It was also observed that five of the seven units had the and the seat. The licensee poppet spring entrapped between the poppet attributed the seven failures in the compression direction to abusive handling during compression of the units for installation following The cause of the single testing at the previous refueling outage.

failure in the extension direction has not been deter =ined.

In addition to exercising greater care in reinstallation, the licensee co==itted te functionally test all Bergen-Paterson snubbert subjected to transient conditions which cause either physical damage to or significant moverer of piping.

This testing will include verification of piston movement, lockup and bleed. The Bergen-Paterson Technical Maintenance Manual rec,o= ends that additional inspections should be made on units which may have participated in an unusual shock occurrence involving kaown danage to". piping or equipment.

On January 3, 1979, the licensee reported that the decay heat re= oval form of a syster had been subjected to a transient condition in tF s

" water hammer." This transient, caused pipe movement great enough to da= age two rigid pipe support wall attachments. The subsequent functional one of seven testing of the af fected Bergen-Paterson units revealed that units failed the lockup test. This unit (Model No. HSSA-3-6) was disassembled and damage to the poppet valve and seat was observed.

The damage to the poppet valves is presently being reviewed by both the licensee and Bergen-Paterson. At this time, the cause of damage has not been completely defined nor has appropriate corrective action been determined. Other licensees have reported instances of poppet valve damage; h'ovever, the cause and extent of damage are not known at this time.

February 2, 1979 IE Information Notice No. 79-01 This information is provided as an early notification of a possibly It is expected that recipients will review the significant matter.

No specific information for possible applicability to their facilities.

If further NRC evaluatier.s action or response is requested at this time.

so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions. If you have questions regarding this matter, please contact the Director of the appropriate NRC Regional Officc.

Page 2 of 2

IE Inf ormation Notice ::c. 79-01 February 2, 1979 LISTING 01 E INFORMATION NOTICES ISSUED IN 1979 Information Subject Date Issued To Notice No.

Issued An Information Notice is a new method of com=unicating items of potential interest to licensees. This ite=, Information Notice No. 79-01, is the first of this new form of co=munication.

e J