ML19261B463

From kanterella
Jump to navigation Jump to search
Ack Receipt of 781011 & s Informing NRC of Steps Taken to Correct Violations Noted in QA Program Insp Rept 99900205/78-01
ML19261B463
Person / Time
Issue date: 12/04/1978
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Carreau G
PROCESS EQUIPMENT CO., INC.
Shared Package
ML19261B464 List:
References
REF-QA-99900205 NUDOCS 7902230144
Download: ML19261B463 (1)


Text

p >" "' C oq'o s

UNITED STATES

~

Iy NUCLEAtt REGULATOftY COMM:5310N A 7' "l'

HEGION IV f.oE G11 RYAN PLAZA DRIVE,SUtTE 1000 e,. 'p g (((

AHLINGTON, TEX AS 7E011 s

y n p December 4, 1978 Docket fio. 99900205/78-01 Process Equipment Company, Inc.

Attn: Mr. G. Carreau Manager, Quality Assurance 71 Forest Street Brockton, MA 02402 Gentlemen:

Thank you for your letters of October 11, 1978, and flovember 21, 1978 in response to our letters of August 25, 1978, and flovember 8, 1978, and discussion with you during a telephone call on November 7, 1978.

We understand that a memoranduin has been issued to all super-visory personnel stating that all temporary attachments welded to a vessel must be identified with naterial type and heat number.

We have no further questions at this time and will review your corrective action during a future inspection.

Sincerely, C_

b.b\\ ;4 {2-4 7

~

Uldis potapovs, Chief Vendor Inspection Branch 7 9 0 2 2 3 0 /4't/