ML19261B119
| ML19261B119 | |
| Person / Time | |
|---|---|
| Issue date: | 12/15/1978 |
| From: | Potapovs U NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Elder J ANDERSON-GREENWOOD & CO. |
| Shared Package | |
| ML19261B120 | List: |
| References | |
| REF-QA-781215 NUDOCS 7902090404 | |
| Download: ML19261B119 (2) | |
Text
'
s 1
- Mo,
UNITED STATES h(
<Y v
o NUCLEAR REGULATORY COMMISSION
[
I' ' A Y
REGION tv
)
[-
611 RYAN PLAZA DRIVE, SUITE 1000 o gg; 3/j ARLINGTCN, TEXAS 76011
- f4 "d'
15 DEC 1979 5.
Docket No.
99900214/78-01 Anderson-Greenwood and Company ATTil:
Mr. J. H. Elder, Jr.
President 5425 South Rice Avenue Houston, Texas 77036 Gentlemen:
This refers to the QA Program inspection conducted by Mr. Wm. D. Kelley of this office on December 4-5, 1978, of yr Jr facility at Houston, Texas, associated with the manufactura of ASME Section III "f!" Class 1, 2 & 3 valves and to the discussion of our findings with Mr. F. Pizzitola and members of your staff at the conclusion of the inspection.
This inspection was made to confirm that, in the areas inspected, your QA Program is being effectively implemented. The inspection effort is not designed to assure that unique quality requirements imposed by a customer are being implemented; nor to assure that a specific product, component or service provided by you to your customers, is of acceptable quality. As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or services procured from others.
You should therefore not conclude that the ilRC's inspection exempts you from inspections by an NRC licensee or his agents nor from taking effective corrective action in response to their findings.
Areas examined during the inspection and our findings are discu sed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector. Within the scope of this inspection, we found no instance where you failed to meet NRC requirements.
In accordance w'th Section 2.790 of the Commission's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of this letter together with the enclosed inspection report will be placed in the Commission's Public Document Room.
If this report contains any informa-tion that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to with-hold such information from public disclosure.
Any such application must include a full statement of the reasons on the basis of which it is Oc 0]0'{D 9
Anderson-Greenwood and Company claimed that the information is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document.
If we do not hear from you in this r egard within the specified period, the report will be placed in the Public Document Room.
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, j
G vQbP Uldis Potapovs, Chier Vendor Inspection Branch
Enclosure:
Inspection Report No.
99900214/78-01
.