Forwards Final Deficiency Rept Re Incorrect Valve Data Used in Piping Analyses of Lines Penetrating Steel Containment Vessel
ML19260E259
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 02/04/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19260E260 List:
References
NCR-CEB-80-2, NUDOCS 8002140349
Download: ML19260E259 (1)


Text

.

TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 374o1 400 Chestnut Street Tower II February 4, 1980 Mr. James P. 'Reilly, Director Office of Inspo tion and Enforcement U.S. Nuclear Reg atory Connaission Region II - Suita 100 101 Harietta Stree Atlanta, Georgia 3 03

Dear Mr. O'Reilly:

SEQUOYAd NUCLEAR PLMT UNIT 1 - INCORRECT VALVE DATA LSE.D Di PIPING ANALYSES OF LINES PthhTRATING THE STEEL CONTAINMENT VESSEL -

NCR CEB 80 FINAL REPORT The subject deficiency was initially reported to NRC-01E Inspector W. T. Cottle on January 4,1980, in accordance with 10 CFR 50.55(e).

Enclosed is our final report.

If you have any questions concerning this matter, please get in touch with D. L. Lambert at FTS 854-2581.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety Enclosure cc: Mr.VictorStallo,Jr., Director (Enclosure)/

Office of Inspection and Enforcement U.S. Sclear Regulatory Commissior..

Washington, DC 20555 Bo/7 ss lll An Equal Opportunity Employer g. e