ML19260D364

From kanterella
Jump to navigation Jump to search
Forwards LERs 80-007/03L-0 & 80-009/03L-0
Date released: 10/01/2019 Download: ML19260D364


LER 80-009/03L-0:on 800111,while Performing Periodic Test on Main Steam Safety Valves,Found Valves SV-MS-101-A & C, SV-MS-102-A & B & SV-MS-105-A & C Did Not Lift at Pressure Setpoints Per Tech Specs.Caused by Setpoint Drift
ML19260D369
Person / Time
Site: North Anna 
Issue date: 02/08/1980
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19260D369 (2)
LER 80-007/03L-0:on 800111,during Mode 3 Reactor Heating Containment Average Temp Decreased to 85 F,Less than Tech Specs.Caused by Insufficient Procedural Precautions. Removed Chiller from Svc.Monitored Temp
ML19260D368
Person / Time
Site: North Anna 
Issue date: 02/08/1980
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19260D368 (2)
Forwards LERs 80-007/03L-0 & 80-009/03L-0
ML19260D363
Person / Time
Site: North Anna 
Issue date: 02/06/1980
From: Stallings C
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References