ML19260D359
| ML19260D359 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 01/31/1980 |
| From: | Mills L TENNESSEE VALLEY AUTHORITY |
| To: | Rubenstein L Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML19260D360 | List: |
| References | |
| NUDOCS 8002080556 | |
| Download: ML19260D359 (1) | |
Text
.
TENNESSEE VALLEY AUTHORITY CH ATTA NCOG A. TEN N ES S EE 0 74 21 400 Chestnut Street Tower 11 January 31, 1980 Director of Nuclear Reactor Regulation Attention:
Mr. L. S. Rubenstein, Acting Chief Light Water Reactors Branch No. 4 Division of Project Management U.S. Nuclear Regulatory Commission Washington, DC 20555
Dear Mr. Rubenstein:
In tne Matter of the Application of
)
Docket Nos. 50-327 Tennessee Valley Authority
)
50-328 Enclosed are ten copies of a revision to the Offsite Dose Calculation Manual (ODCM) for the Sequoyah Nuclear Plant. This revisicn incorporates a summary of plant procedures regarding effluent monitoring instrument setpoint de. termination and tank mixing requirements before sampling.
Please incorporate these change pages into the copy of the ODCM that was transmitted to you in my letter dated July 17, 1979.
If you have any questions regarding the Sequoyah Nuclear Plant ODCM, please get in touch with M. J. Burzynski at FTS 854-2581.
Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety Enclosure
/6(\\
8002080 m,1;,c=m, 2-=
,