Submits Addl Info Re Defective Top Cover Gaskets in Namco EA-180 Limit Switches.Determines That No Problem Exists Since Normal Ambient Temp in Reactor Containment Bldg Less than 175 F.Not Deemed Reportable Deficiency
ML19260C898
Person / Time
Site: Waterford 
Issue date: 01/31/1980
From: Aswell D
LOUISIANA POWER & LIGHT CO.
To: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
LPL-13057, NUDOCS 8002060445
Download: ML19260C898 (1)


Text

m I

3_Q_g LoulSIANA P O W E R & L I G H T[ P o BOX 6008 + NEW CALEANS. LCUIS!ANA 70174 442 ca,AcNcE sma 8'

  • (504) 366 2345

'SSO5vsY$

January 31,1980 u

g Vce P*wm-Power Producten LPL 13057 Q-3-A35.07 Mr. K. V. Seyfrit, Director, Region IV U. S. Nuclear Regulatory Con: mission Office of Inspection and Enforcement 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76012

SUBJECT:

Waterford SES Unit 3 Docket No. 50-382 Potential Construction Deficiency Report Defective Top Cover Gaskets NAMCO EA-180 Limit Switches

Reference:

LPL 12566 dated November 3, 1979

Dear Mr. Seyfrit:

We have completed our review of the subject potential construction deficiency concerning the subject NAMCO EA-180 Limit Switches.

NAMCO has informed us that if these switches are in a continuous ambient temperature of 1750F or less, no action is necessary.

Since the normal ambient temperature in the Waterford 3 SES Reactor Containment Building is less than 175 F, we have determined that no problem exists and this will not be considered a reportable construction deficiency.

Yours very truly, D. L. Aswell

.g 9

.)

i

'i -

DLA/TFG/grf cc: Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Director Office of Management Information and Program Control h<

O U. S. Nuclear Regulatory Commission 3

0 Washington, D.C.

20555 L

80020604-+5

-. _ -