.e
]D"*]D
]DlT hf M J o o Ju o h lA A Ifd_m SEP 131979 MEMORANDUM FOR:
N. Su, Task Manage A-39 Division of Syst Safet i
FROM:
V. S. Noonan, Chief. Engineering Branch Division of Operating Reactors r-
SUBJECT:
FSI EFFECTS DURING SRV T-QUENCHER DISCHARGE BUBBLE OSCILLATIONS The Engineering Branch, DOR, has reviewed the Monticello T-Quencher Test Report, NEDE-21864-P along with the results of a study performed by our consultant Lawrence Livermore Laboratory on fluid structure interaction effects in the Mark I Suppression Chmber, NUREG/CR-0746.
Based on our review of the test results we have concluded that fluid structure interaction effects were not significant in reducing the maximum pressures measured during the Monticello T-quencher tests. A copy of our evaluation is attached.
Original signed bys Vincent S. Noonan, Chief Engineering Branch Division of Operating Reactors
Enclosure:
As stated
Contact:
J. R. Fair, D0R x27357 cc:
D. Eisenhut B. Grimes i: 2 [
C. Grimes J. Kudrick G. Lainas W. Butler S. tu <ttt) b 1702 355 1
/
,m
.[,
EB_:D,0R,:fQ EB:D0R8
.,...xi c.hma n,,,,,M,Nggn d.,
,?
.JFair 9ug.a9_.
9aaa9..
9 dom...
o c -.. <,.u -
8 001080 P@
'