9 (.,. O-TI"gt/,T g

/

e nua i

[o, UNITED STATES

[,

p, NUCLEAR REGULATORY COMMISSION

[ ) g( (,E WASHINGTON, D. C. 20555

%.J A,o$

DEC 0 41979 MEMORANDUM FOR: Those on Attached List FROM:

J. R. Strosnider, Manager TAPS A-3 and A-5 Engineering Branch, 00R F. M. Almeter, Panager TAP A-4 Engineering Branch, D0R

SUBJECT:

SANDIA STATISTICAL ANALYSES OF STEAM GENERATOR INSERVICE INSPECTION Attached is a copy of a final draft report on the statistical aspects of steam generator tube inservice inspections.

This report has been prepared by Sandia National Laboratory under an Engineering Branch technical assistance program. This report is a significant part of Task Action Plans (TAPS) A-3, A-4, and A-5.

Results of this study, along with results of systems analyses which are being performed, as part of the TAPS, will be used as bases for the establishment of steam generator inspection requirements.

Because of the significance of this report we are requesting a careful review before it is released.

Please provide any coments, criticisms, or suggestions on the draft report by December 12, 1979, A

. A,,,.

N NC'

'Y :?J2:U.e :

Jack R, Strosnider, Manager TAPS A-3 & A-5 Engineering Branch Division of Operating Reactors YMk !'?% Yr$.

Frank M. Almeter, Panager TAP A-4 Engineering Branch Division of Operating Reactors cc:

M. Ayco 1700 117 h

B WO s

e e

t.r 1 1 1979 Addresses for Memorandum dated D. G. Eisenhut S. H. Hanauer L. C. Shao V. S. Noonan B. D. Liaw W. Hazelton E. Murphy L Frank 1700 118