Form NRC418 U.S. NUCLEAR REGULATORY COMMISSloN U

CERTIFICATE OF COMPLIANCE 10 C R 71 For Radioactive Materials Packages 1Ja) Certificate Number 1.(b) Revision No.

1.fc) Package identification No.

1.(d) Pages No. 1.(e) Total No. Pages 6078 5

USA /6078/AF 1

3

2. PR E AMB LE 2.tal This certificate is issued to satisfy Sections 173.393a.173.394,173.395, and 173.396 of the Department of Transoortation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangs mus Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Titte 10, Code of Federal Regulations. Part 71, ** Packaging of Radioactive Materials for Transpor; and Transportation of Radioactive Mate,ial Under Certain Conditions."

2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Depar ment of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application--

3.(a)

Prepared by (Name and.ddress):

3.(b)

Title and identification of report or application:

Combustion Engineering, Inc.

Combustion Engineering application dated 1000 Prospect Hill Road July 3, 1969, as supplemented.

Windsor, CT 06095 3.(c)

Docket No.

71-6078

4. CONDITIONS This certificate is conditional upon the fulfilling of t!.e requiremerits of Subpart O of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
5. Descripnon of Packaging and Authorized Contents Model Number, Fissile Class Other Conditions, and

References:

(a) Packaging (1) Models Nos.: 927Al and 927Cl (2) Description A steel fuel bundle shipping container consisting of a strongback and fuel bundle clamping assembly, shock mounted to a steel outer container. A minimum 1/4" thick, 6" x 6" x 8" high steel separators are bolted between fuel bundles. The !!odel 927Al container is approximately 43" in diameter by 189" long with an approximate gross weight of 6,200 lbs. The Model 927C1 container is approximately 43" in diameter by 216" long with an approximate gross weight of 7,000 lbs.

(3) Drawings The Model 927Al container is constructed in accordance with Applied Design Company Drawing No. 927A1, Sheets 1, 2 and 3 as revised by Applied Design Company Drawing No. 927Al (modified) Sheets 1, 2 and 3.

The Model 927Cl container is constructed in accordance with Applied Design Company Drawing No. 927Cl, Sheets 1, 2 and 3.

1616 002 7912260 h[

i s

71-6078 Page 2 - Certificate No. 6078 - Revision No. 5 - Docket No.

l 5.

(b) Contents (1) Type and form of material Palisades fuel bundles consisting of 0.359" diameter (i) uranium dioxide pellets clad in 0.024" thick zircaloy tubes in a 15 x 15 square array with a 0.550" pitch.

Each fuel bundle consists of a maximum of 164 fuel rods at 3.2 w/o enrichment in the U-235 isotope and 48 fuel rods at 2.54 w/o enrichment in the U-235 isotope.

Mark V fuel bundles consisting of 0.380" diameter (ii) uranium dioxide fuel pellets clad in 0.26" thick zirca?oy tubes in a 14 x 14 square arrary with a 0.580" pitch.

Each fuel bundle consists of a maximum of 176 fuel rods at 3.5 w/o enrichment in t.v. U-235 isotope.

Arkansas fuel bundles consisting of 0.325" diameter (iii) uranium dioxide pellets clad in 0.25" thick zircaloy tubes in a 16 x 16 square array with a 0.605" pitch.

Ea::h fuel bundle consists of a maximum of 236 fuel rods at 3.5 w/o enrichment in the U-235 isotope.

(2) Maximum quantity of material per package Two (2) Palisades fuel bundles containing not more than 25.7 Kgs U-235; or Two (2) Mark V fuel bundles containing not more than 29.4 Kgs U-235.

Two (2) Arkansas fuel bundles containing not more than '

29.8 Kgs U-235.

III (c) Fissile Class Maximum number of packages Eight(3) per shipment Each fuel assembly shall be unsheathed or shall be enclosed in an 6.

unsealed, polyethylene sheath which will not extend beyond the ends of the fuel assembly. The ends of the sheath shall not be folded or taped in any manner that would prevent flow of liquids into or out of the sheathed fuel assembly.

1616 003

71-6078 Page 3 - Certificate No. 6078 - Revidon No. 5 - Docket No.

The upper bundle bracket may be secured to the strongback by either of 7.

the following hardwares:

(1) Ten, 3/4-16 UNF Hex Head bolts with associated washers and nuts, or Eight, 3/4-inch diameter steel clevis pins with associated steel (ii) hair pin cotters, and two, 3/4-16 UNF Hex Head bolts with associated washers and nuts. The two bolts (Part No. 27) shall be placed in the uppermost position for that specified part.

The package authorized by this certificate is ilereby approved for 8.

use under the general license provisions of 10 CFR 571.12(b).

9.

Expiration date: March 31, 1980.

REFERENCES Combustion Engineering, Inc. application dated July 3,1969.

Supplements dated: August 19, 1969; February 23, May 20, and June 21, 1971; July 7 and September 23, 1975; and May 3 and November 30, 1978.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION b.,

Charles E. MacDonald, Chief Transportation ^.ertification Branch Division of Fue'. Cycle and Material Safety Date:

1616 004