Text
/J SIC
'o UNITED STATES 8 }* ) y ,,g NUCLEAR REGULATORY COMMISSION c
REGION V g,l g o, - g '
g 1990 N. CALIFORNI A BOULEVARD
%'O e
SUITE 202, WALNUT CREEK PLAZA
- e,,*
WALNUT CREE K, CALIFORNIA 94596 NOV 131979 Docket No.70-754 General Electric Company Vallecitos Nuclear Center P. O. Box 460 Pleasanton, California 94566 Attention: Mr. R. W. Darmitzel, Manager, Radiation Processing Operation Gentlemen:
Subject:
Inspection of Vallecitos Nuclear Center This refers to an inspection conducted by Mr. W. J. Cooley of this office on September 18-21, 1979, of activities authorized under NRC License No. SNM-960 and to the discussion of the findings held with members of your staff at the conclusion of the inspection.
Areas examined during this inspection are described in enclosed inspection report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.
No items of noncompliance with NRC requirements were identified within the scope of this inspection.
In accordance with Section 2.790 of the NRC's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.
If this report contains any information that you believe to be proprietary, it is necessary that you submit a written application to this office, within 20 days of the date of this letter, requesting that such information be withheld from public disclosure.
The applica-tior, must include a full statement of the reasons why it is claimed that the information is proprietary. The application should be prepared so that any proprietary information identified is contained in an enclosure to the application, since the application without the enclosure will also be placed in the Public Document Room.
If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.
Ik 7012180O N 16M 152
_2_
Should you have any questions concerning this inspection we will be glad to discuss them with you.
Sincerely, S
lt H. E. Book, Chief, Fuel Facility and Materials Safety Branch
Enclosure:
IE Inspection Report No. 70-754/79-09
\\\\
16N 153