ML19260B418

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info for Review of Model Lithium Hydroxide Fire & Impact Shield Shipping Package
ML19260B418
Person / Time
Site: 07109851
Issue date: 11/20/1979
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Ross D
ENERGY, DEPT. OF
References
NUDOCS 7912100149
Download: ML19260B418 (2)


Text

.

pn nea.g e

jo UNITED STATES

,y_R cjc E g

NUCLEAR REGULATORY COMMISSION o

$ b %.s Q^

WASHINGTON, D. C. 20555 g

p NOV 2 0 879 FCTC:WHL 71-9851 U.S. Department of Energy ATTN:

Dr. Donald M. Ross Washington, D.C.

20545 Gentlemen:

This refers to your letter dated July 31, 1978, requesting our review of the Model Lithium Hydroxide Fire and Impact Shield shipping package.

In connection with our review, we need the infortia', ion icientified in the enclosure to this letter.

Please advise us within thirty (30) days from the date of this letter, when this information will be provided.

Sincerely, G&*ASL Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety

Enclosure:

As stated cc:

US DOE, Oak Ridge Oper. Off.

ATTN:

Mr. William H. Travis P.O. Box E Oak Ridge, TN 37830

\\5\\8 D\\8 7913100 )% c

U.S. Department of Energy ORNL Lithium Hydroxide Fire And Impact Shield Shipping Container NOV 2 01979 Encl to ltr dtd:

GENERAL 1.

Identify and provide d"awings and specifications for the specific inner container designs to ba used for normal form shipments, and show that they satisfy the esta5.lished containment criteria following the tests in Appendices A and B of 10 CFR Part 71.

2.

Provide drawings and specifications for any inner containers that are to provide gamma shielding.

CONTAINMENT 1.

Develop a containment acceptance criteria for normal conditions of trans-port and accident damage conditions for the normal form shipments.

Regulatory Guide 7.4 may be used in establishing this criteria.

2.

Revise the containment analysis provided in Section 3.2 in Report No.

ORNL/ENG/TM-8 to show that the criteria established in Item 1 above is met for all normal form containers and normal conditions of transport.

3.

Show that the containment criteria established is satisfied by the tests described in Item 3.3 of Report No. ORNL/ENG/TM-8 for accident damage conditions.

Provide a similar demonstration for any additional normal form containers.

4.

Show how the requirements of 10 CFR 671.42 will be met for normal form and special form material containing plutonium.

TESTING AND MAINTENANCE Provide a description of the containment testing program, and show that the sensitivities and testing sciiedules are adequate for safe use of the packages.

Regulatory Guide 7.4 may be used for pariodic testing.

For assembly verification it is recommended that a test of sufficient sensitivity to limit the maximum release to a type _A quantity in 10 days is used, however, a leak test sensitivity 3

greater _than lx10 3 at-cm /sec, would not be required.

ihe_minircum sensitivity of lx10 1 3

at-cm /sec (air at 1 atm and 25 C leaking to a 10 2 at ambient) as specified in ANSI N14.5 should be met.

SHIELDING Show that the specific inner containers that provide gamma shielding meet the requirements of 71.35(a) and 71.36(a).

1518 019