ML19260A775
| ML19260A775 | |
| Person / Time | |
|---|---|
| Site: | University of Missouri-Columbia |
| Issue date: | 10/23/1979 |
| From: | Brugger R, Olson O MISSOURI, UNIV. OF, COLUMBIA, MO |
| To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| Shared Package | |
| ML19260A774 | List: |
| References | |
| NUDOCS 7912030220 | |
| Download: ML19260A775 (1) | |
Text
Research Reactor Facility UNIVERSITY OF MISSOURI Research Park Columbia Missouri 65211 October 23, 1979 Telephone (314) 882-4211 U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region III 799 Roosevelt Road Glen Ellyn, IL 60137
Reference:
Docket No. 50-186 University of hfissouri License R103
Subject:
Response to inspection report 50-186/79-06 Gentlemen:
The following corrective action for an item of non-compliance noted by hir. J.
W. Hiatt during an inspection September 11-13, 1979 is submitted for your review.
Notice of violation 10CFR 71. 62 (a) (10) requires that records of the results of determinations required by 10CFR 71.54 " Routine Determina-tions," be maintained.
Corrective Action Immediately following verbal notification by h!r. Hiatt of the violation, supervision informed appropriate individuals to use a check-off sheet for every shipment included in the scope of 10CFR 71.54.
The check-off sheet assures performance of all requried steps and is filed as the record required by 10CFR 71. 62 (a) (10).
Sincerely yours, OrvaL4. Olson, blanager Rea c't o r Iealth Ph ics s
o b e r t 31.
r gge Director 1460 359 QF$y OLO/mbs at
'a p
COLUMBIA KANSAS CITY ROLLA ST. LOUIS 7 912 0 30 L 2 O an equal opportunitbniditution1979 OCT