f/c2

, go. ws q==c?

M7 W.

MISSISSIPPI POWER & LIGHT COMPANY ll /

Helping Build Mississipin P. O. BOX 1640. JACKSON. MIS SIS SIP PI 39205 P.e ' e D y. TION D t. P A,e T SA E *. T Office of Inspection and Enforcecent October 31, 1979 l'.

S. Nuclear Regulatory Commission Region 11 101 Marietta Sutect, N.W., Su ite 3100 Atlanta, Georgia 30303 o

Attention:

Mr. J. P. O'Reilly, Director

Dear Sir:

SUBJECT:

Grand Gulf Nuclear Station 0260/0472/L.'.01.0/15521 Evaluation of IE Bulletin 79-23 AEC1-79 /123 Nnc IE Bullet in 79-23, " Emergency Diesel Generator Field Ixciter

. ransf orme r," e::prenes a c oncern rega rding error in t he wi ring of eme r-gency diesel generator f ield excit e r t ransformer s.

In the desir.n of the Grand dul f Nuclear Stat ica Unit s 1 and 2, the excit er t ranst orner wind ing cour:ec t ionr. are wye-wye not wye-dolta, as deu r ibed in the bulletin.

This eliminates any probica of circulating current 1: the secondary.

l'a r t.' of thts bulletir. r. quires field load operation testing of the c:ne r,:e n c y liesel gene rators for a duration not less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

This testinf, will be addressed in the plant Technical Specifications.

In addi-tlon, load testing that will satisfy the requirements of this bulletin will be conducted prior to fuel load.

Yours truly, 1

/,:,/ f A t_.

- (

L.

F. Dale Nuclear Project Manager RT!:/JI:R:dwe cc-Mr.

N.

l..

Stampley

?!r.

R.

11. NGehee

!!r. Y.

B. Ccuner

,j

(

e-I)

(

J)

Mr. Victor Stello, Jr.. Directcr Division of Inspect ion a Enforcement U.

S.

Nuc lea r Kegula tory C aission Waahingt :n,

D.

C.

20355 e

ntiesht"'"

vem e Midoie se ;tn t,-

~911210