ML19259C781

From kanterella
Jump to navigation Jump to search
Forwards Westinghouse Tm Anderson Re Deficiency on Reactor Trip Initiation from Steam Generator Level
ML19259C781
Person / Time
Issue date: 07/09/1979
From: Jordan E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To: Brunner E, Heishman R, Long F
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I), NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II), NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19259C782 List:
References
NUDOCS 7908150161
Download: ML19259C781 (1)


Text

.

r %'o U.NITED STATES

- O.,, r,f '^n NUCLEAR REGULATORY COMMISSION

..., ad i W ASW NGT O N, 0. C. 20555

,Q

%' ~& Ay

.~%

117 j v

JUL 9 W3 O

/

s MEMORANDUM FOR:

E. J. Brunner, Chief, RO&NSB, RI F. J. Long, Chief, RO&NSB, RII R. F. Heishman, Chief, RO&NSB, RIII G. L. Madsen, Chief, RO&NS3, RIV J. L. Crews, Chief, RO&NSB, RV FROM:

E. L. Jordan, Assistant Director for Technical Programs, IE

SUBJECT:

CORRECTION TO REACTOR TRIP SETTINCS ON STEAM GENERATOR WATER LEVEL (AITS H07001940)

The enclosed letter to Victor Stello from T. M. Anderson of Westinghause of June 22, 1979 defined a significant deficiency en the initiat' on of a reactor i

trip from steam generator ievel.

Mr. Anderson, also, stated in the letter that recommended actions had been presented to Westinghouse customers.

We are requesting that you survey the operating Westinghouse facilities in your Region and verify that the recomendations have been received and the date that they were implemented.

The survey may be by telephone.

Please forward the results of the survey to H. A. Wilber (492-8180) before close of business on July 13, 1979.

pb-Marc,'. verdan, Assistant Director for bchnical Fregrams Division of Reactor Cperations Inspecticn

Enclosure:

As stated cc:

N. C. Moseley S., E. B rya n LSSDB 7 008150 /b b

O