muu%tv.
M o 'UC M
/Tkb Ihe / /CL
'y-SM.%
PHILADELPHI A ELECTRIC COMPAW, Peach.Borroer Atwie Power Station-Delta, Pennsylvenim 17514 May 17, 1979L Mr. Boyce II. Crier Office of Inspection: and Enforcement D h @ M<
Region I.
bbI United. Staret Nuclear Regulatory Commission-
@D
@'T P'
63I Farlo Avenue 1 1 f
ring of Prussia. PA 19406-d J
E Li 6
SUILIECT':
REPORTfMI'E OCCURRENCE.- PRO W hUTIFICATION.:
Confirainc W.. T. If11 rich's conversation: vi th Mr.. Greenman, Region.1,.
United States Nuclene Regulatory Commission: on 5/17/79'.
Reference:
. Docket No. 50-277 and 50-27%
Peach Pottose Units-I and: 3 Technicat Spectfication.
Reference:
- 6.9,2.a(97 Report No.. 2-79'-24/ IP occurrence Date-5 tay 17, 1979 Identificacion of Occurrencee CRD return line. outside of contaimment support does not. seer seismic requirements.
Condi*tions P'tior te Occurrence:-
Unir. 2. shutdown. fore maintwnance curage.-
Unit 3 operating at approminatwly 901. power Apparent Cause of' Occurrencec Seismic support. 21culations. tw response to t.E'. BuHetini 79-04t have indicated. that the support for the outboard CRD piping, is. unsatisfactory
_Aneiysis. oF occurrencet The-contml. rod de:ive systm has. been'. operatet at Peach Ebetoes wi.th the returrr line to the reactor / isolsted' for the lass: 2. operating: cycles.. CRD-systeur is ful:Iy operativn=4 En this ante of operatfors The line irr question; is. therefore inscrive.
Calculationw have detenmined that the CRD recurrs line piptng betweeni the coneni.reent sheII and..the" reactor.vessrF. is property supporteli.:. This p'epimg contains a cherir valve wh4che 11r: closed:,in the pressnet mode cfrc.operneterr,.. Thk check..v.s4ve a= *<etI! as-the outer check valve wasr sattsfactor.i f y ter.k rested durimg the nose recent refu' eling outage:
Since-this inner.va.1.v.c. i s leak tightwe is presentlyr ciesA and is: Iocated int pipst:gr which: is seisai;cally quali.fi~cd,. the inadequate setswic supporr ofi the piping.-
and, check vaixe outside of contusnmenr. has. minimal safety signif1'cance.. -
.,;c. m. 7906270Ckh.
S
~"
i v 7ec w ce Corrective.Actiun.:
The Philadelphi m ETeerric Company ** responser to T.E. Buttettu 79-04:
dated S/1/79 Indiented that: if the scismie ana,1ysis of the outboarda-CRD piping imlicatal modi.ficaciant were requirred',. these moJEfications would be coep14ted in an. expeditious manner.
The Philadelphira. Elee.tric Company's ArchsteeJrucak Engineer-is: present2.y desisgning addi,Moruck supports for-the outbvanli CRD piping..
The design. for-these. additional supports ie expect's d! em be cosphredi for Utsit 2' on 5/21'. and'. for Unirs. 3 on.5/23 These suppores will be instartled, as, rapid 2gr as possiMe oncw ther design, is availa'o4e Previous. Fai,Iures:.
N/'A.
Very tru5y yours,,
h*?h/
YY.
W.. T tit'Prichy Supenintrendent -
Peacht BottoniAronicE4mer Statiem-hTU::1)ht OO' 9
a
~
. o ;,..
g i.
d w JU
. J.J
. J
-3
~
.c
^ ' ~ ~
+. '........
-.. - ~
..~ ~~'
- ~
~
..: - ~ ' -- - -
-. - ~
.