Submits Addl Info Re Steam Generator Feedwater Piping,In Response to 790525 Request.Oversized Drawing in Central Files Only.Addl Info Will Be Forwarded
ML19259C494
Person / Time
Site: Maine Yankee
Issue date: 06/18/1979
From: Groce R
Maine Yankee
To:
Office of Nuclear Reactor Regulation
References
WMY-79-64, NUDOCS 7906220196
Download: ML19259C494 (1)


Text

>

~

RIAIRE HARHEE 'Amml0POWERCOMPARU*

, u ~ "o o. ",,

71, w.s,noao vissacuuse m oisa,

'y y ENGINLER;NG Of FICE 617-366-9019 O

B.3.2.1.

WMY 79-64 June 18, 1979

\\

United States Nuclear Regulatory Commission Washington, DC 20555 Attention:

Office of Nuclear Reactor Regulation

Reference:

(a) License No. DPR-36 (Docket 50-309)

(b) USNRC Letter to MYAPC dated May 25, 1979

Dear Sir:

Subject:

Steam Generator Feedwater Piping Reference (b) requested information concerning the steam generator feedwater piping at Maine Yankee Atomic Power Station. This letter responds to the first four items of that request:

1. contains drawings for the feedwater piping inside containment. The piping is Schedule 80; the nozzle is machined to Schedule 80 dimensions.

4 2.

The piping system was designed to Power Piping Code ANSI B31.1-1967. Deadweight stresses were limited to 1500 psi by design.

3.

The feedwater sparger is not welded to any pressure retaining material. The feedwater piping is ASTM A106 Grade B; the feedwater nozzle is ASME SA-508 Class 1. '

4.

The nozzle to pipe weld was performed using a GTAW root pass with a consumable insert followed by SMAW using 7018 electrodes.

The final welds were radiographed. Preheat and post weld heat treatment are not required for those materials. The weld joint geometry consists of a 37 degree bevel with a 1/16 inch land.

Since the nozzle thickness is greater then the Schedule 80 thickness for the feedwater pipe size, a 4 to 1 taper was used from the counterbore and outside dimension of the weld prep.

t The remaining information will be provided within 40 days, as permitted j

by Reference (b).

Should you have any questions, please contact us.

Very truly yours, 2281 122 MAINE YANKEE ATOMIC POWER COMPANY

[N ep 0 M l

JRH/rs Robert H. Groce

[

r [ronck Licensing Engineer 790622019(,4 Enclosure 49 6ze 0) po/