ML19259B808

From kanterella
Jump to navigation Jump to search
Potential Conceptual Design Requirement:Licensee Reported Possible Insufficient Bend Radius for Seismic Conditions in Termination Cables.Situation Under Evaluation
ML19259B808
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 11/13/1978
From:
SOUTH CAROLINA ELECTRIC & GAS CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 7903230189
Download: ML19259B808 (1)


Text

,

y., l . v' _ ,

s TELEPHONE REPORT l . .

( .

t FACILITY: Sut::mer Unit 1 50-395 DOCKET f:

DAIZ: 11/13/78 4:30 pm TM. LIC, OCC. #:

SUBJECI: Potential CDR - Insufficient Bend Radius For Cable Terminations

~

~ -

DESCRIPTION OF OCCURSESCE: The licensee reported that there may be an insufficient tend radius for seismic conditions in termination of cables. Licensee is evaluating. Report due 12/13/78.

Contact:

Any Wactor 799-1234 ext. 2294.

~

E' ,

t. .

s' e.

eh 6

g.

.s

~

$_b j&Wo

. b 7903230t89