ML19259A674

From kanterella
Jump to navigation Jump to search
Responds to NRC Ltr Re Violation Noted in Insp Repts 50-245/78-39 & 50-336/78-36.Corrective Actions:Survey Equipment Taken Out of Svc Until Operability & Calibr Can Be Verified
ML19259A674
Person / Time
Site: Millstone  
Issue date: 12/18/1978
From: Counsil W
NORTHEAST NUCLEAR ENERGY CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19259A673 List:
References
NUDOCS 7901100057
Download: ML19259A674 (1)


Text

.

NORTHEAST tmLMES 3

{

f unecucur ici L

tT;

"rs;0%;"JM**"'

December 18, 1978 Docket No. 50-245 50-336 Mr. Boyce H. Grier, Director U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region I 631 Park Avenue King of Prussia, PA 19406

Reference:

NRC Inspection 50-245/78-39; 50-336/78-36

Dear Sir:

On December 14, 1978 during NRC Inspections 50-245/78-39; 50-336/78-36, your inspector verified in the presence of our representatives deficien-cies in the operability of certain of our portable radiation survey instrumentation.

As a result, all Eberline PIC-6A and Teletector Survey Instruments were inmediately removed from service and will remain out of service until their operability and calibration have been verified.

In addition, Northeast Nuclear Energy Company will, within forty-five (45) days, revise procedures as necessary for the. calibration and control of our portable radiation instrumentation pursuant to Section 6.8 of our Technical Specifications.

Very truly yours, NORTHEAST NUCLEAR ENERGY COMPANY W. G. Counsil Vice President WGC/kwc BY:

W. F. Fee Vice President 79011000 57