ML19257C277

From kanterella
Jump to navigation Jump to search
Forwards Primary Containment Leak Rate Testing, for 1978-79
ML19257C277
Person / Time
Site: Vermont Yankee Entergy icon.png
Issue date: 01/21/1980
From: Rich Smith
VERMONT YANKEE NUCLEAR POWER CORP.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML19257C278 List:
References
WVY-80-16, NUDOCS 8001250477
Download: ML19257C277 (1)


Text

.

VERMONT Y AN KEE N UCLEAR POWER CORPOR ATION k 16 RU L, N \ t NT 05 O1 REPLY TO:

ENGINEERING OFFICE TURNPlKE RC AD WEST DORO. M ASS ACHUSETTS 015 81 TELEPHONE 617-3 6 6-9 01 t January 21, 1980 United States Nuclear Regulatory Commission Washington, DC 20555 Attention: Of fice of Nuclear Reactor Regulation

Reference:

(a) License No. DPR-28 (Docket No. 50-271)

Dear Sir:

SuSject: Primary Containment Leak Rate Testing In accordance with the requirements of the Vermont Yankee Technical Specifications, Appendix J to 10 CFR 50 and Regulatory Guide 10.1, we hereby submit 12 copies of the report entitled, " Vermont Yankee Primary Containment Leak Rate Testing 1978-1979".

We trust this information is acceptable to you; however, should you have any questions, please contact us.

Very truly yours, VERMONT YANKEE NUCLEAR POWER CORPORATION 1'?

Robert L. Smith Licensing Engineer RLS/kaf Enclosure 1809 5 8001250 37 f