Responds to NRC Re Violations Noted in IE Insp Repts 50-329/79-22 & 50-330/79-22.Corrective Actions: Welders Reinstructed on Weld Rod Control & Training Session Was Conducted
ML19257A558
Person / Time
Site: Midland
Issue date: 11/30/1979
From: Howell S
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19257A556 List:
References
NUDOCS 8001040625
Download: ML19257A558 (3)


Text

.

t CORSumBfS L Power C0mpBDy S'*"""~'"

Senior Vice Presdent General offices: 1945 West Pernell Road, Jackson, Michigen 49201 * (517) 788 4453 November 30, 1979 Howe-297-79 Mr J G Keppler, Regional Director Office of Inspection und Enforcement US Nuclear Regulatory Co==ission Region III 799 Roosevelt Road Glen Ellyn, IL 60137

~

MIDLAND NUCLEAR PLANT -

INSPECTIO:; REPORT NO 50-329/79-22 AND NO 50-330/79-22 The enclosure to this letter is a response to your letter of October 30, 1979, which transmitted the subject Inspection Report and which requested our written statement on an itet of noncompliance.

'eCL WRB/lr

Enclosure:

Consumers Power Company's Response to Inspection Report No 50-329/79-22 and No 50-330/79-22 1689 179 DEO 8001040

~

CONSUMERS POWER COMPANY RESPONSE TO ITEM OF NONCOMPLIANCE DESCRIBED IN NRC INSPECTION REPORT

_(NO. 50-329/79-22) (NO. 50-330/79-22)

TWO PORTABLE ROD OVENS NOT ENERGIZED _

(50-330/79-22-02)

I Description of Noncompliance Appendix A of Report No 50-329/79-22 and 50-330/79-22 provides the following:

' Activities "10 CFR 50, Appendix B, Criterion V, states in part, that, affecting quality shall be prescribed by documented instruction,

. and shall be accomplished in accordance with these procedures,.

instructions, procedures, Bechtel Quality Assurance Mahual ASME Section III Nuclear Components

. Requirements Division 1, paragraph Slh8, states in part, that, for receipt, inspection, storage, issue and return to stock of velding filler materials are in WFMC-1.

Becht el Power Corporation Procedure Specification No. WFMC-1, Revision 6,

'The portable Amendment 9, paragraph 6.5.8.1, states, in part, that, warmers shall be energized within three hours of the electrode issuance from the rod room.

Contrary to the above, the inspector established the following:

00 p.m. a portable oven with a.- On October 9, 1979, approximately 3:

I.D. No. 288, containing approximately 30 sticks of 3/32" diameter E7018 velding rods was left unenergized 'n the Unit 2 Containment The velding Building adjacent to the Emergency Personnel Hatch.The velding rods were iss rods were cold to touch.

on veld No. M326-2880W, cf Systems No. 3 0"-2HBC-110-H9 on drawing No. 619-2-9 approximately 2:00 p.m., a partable oven with On October 10, 1979, I.D. No. 286, containing approximately 60 sticks of 3/32" and 1/8" b.

diameter E7018 velding rods was left unenergized in the Unit 2 Containment Building at approximately elevation 611'

-0" and 270 The velding rods The velding rods were cold to touch.

were issued to be used on veld No. M326-2h96W, of system No. 10" -

azimuth.

2HBC.110-H28, on drawing No. 619-2-30.

00 a.m. on the The portable ovens were is ued to the velders at 7:

days in question according to the logs kept at the rod room.

c.

has been performed at the time when the conditions were No veldinF noted because no veld rod stub was in the stub can."

~

d.

1689 180 v

2

Response

Bechtel has taken the following actions:

1.

The offending velders were immediately reinstructed on veld rod control and emphasis was placed on portable varmer energizing requirements.

2.

A documented training session was conducted by Bechtel site management.

In attendance were various craft and area superintendents, lead field engineers, assistant lead field engineers, and the assistant subcontracts manager.

3 Bechtel supervisors and field engineers are concentrating on this subject to assure conformance to opecification requirements.

h.

Bechtel Field Engineering has re-issued the " General Instructions to Welders" which is given to velders upon satisfactorily passing the velders' qualification tests.

Each velder is required to sign a statement that says, "I have yead and undcrctand the ' General Instructions to Welders.'"

These instructions also have been issued in French due to the number of Canadians on the project.

With these actions completed, full compliance has been achieved.

WRB/lr 11/28/79 O