ML19257A335
| ML19257A335 | |
| Person / Time | |
|---|---|
| Site: | Hatch |
| Issue date: | 12/31/1979 |
| From: | Kelly R GEORGIA POWER CO. |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML19257A336 | List: |
| References | |
| NUDOCS 8001030770 | |
| Download: ML19257A335 (1) | |
Text
Georgia Power Company 230 Peachtree Street Post Office Box 4545 Attanta, Georgia 30302 Telephone 404 522-6060 hce' Pre dent and Genera! ManagerDecember 31, 1979 Power Generation n,,
g, 7,,,, g.,7 7 Director of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.
20555 NRC DOCKETS 50-321 AND 50-366 OPERATING LICENSES DPR-57 AND NPF-5 EDWIN I. HATCH NUCLEAR PLANTS UNITS 1 AND 2 SPENT FUEL POOL STORAGE EXPANSION Gentlemen:
Georgia Power Company hereby submits Amendment 5 to the report entitled " Spent Fuel Pool Modification" which was included as part of our July 9, 1979, application for expansion of the spent fuel storage capacity at Plant Hatch Units 1 and 2.
This amendment documents the results of our evaluations regarding fuel impact loads and fuel pool structural loads. This amendment also completes our responses to questions contained in your letters dated August 24, 1979, and September 28, 1979, and requests for additional information by your staff during the site visit on November 1, 1979.
Again, as discussed in our letter dated January 9, 1979, we wish to reiterate the need for your expeditious review and approval to allow installation of the high density spent fuel storage racks to begin by March 1980 in order to minimize personnel exposure to radiation. Please advise us if any additional information is needed by your staff to facilitate the timely completion of their review in order to support this schedule.
Very truly yours,
,L
'f hNL
(,% ; IL. A)
R. J. Kelly JAB /TMM/wb Enclosure Sworn to and subscribed before me this 31st day of December, 1979.
$NLLl3 N kWLfun Notary Public shasyMas,teenpa, mate at tarse xc:
Ruble A. Thomas th Comraiselon tgires Feh 22.1983 George F. Trowbridge, Esquire R. F. Rogers, III OlW%@ ]