Metropoliun Edism1 Company Post Office Box 480 I
Middletown Pennsylvania 17057 717 944 4 041 Writer's Direct Dial Number December 24, 1979 GQL 1539 D. G. Eisenhut, Acting Director Division of Operating Reactors Office of Nuclear Reactor Regulations U. S. Nuclear Regulatory Commission Washington, D.C.
20555
Dear Sir:
Three Mile Island Nuclear Station, Unit I License No. DPR-50 Docket No. 50-289 Inacvertent Reactor Scram / Safety Injection This letter concerns your letter of September 21, 1979, discussing the inadvertent reactor scram and safety injectf.n which occurred during monthly surveillance testing of the safeguards system.
Met-Ed has not completed the required reviews needed to fully respond to the subject letter. These reviews are being conducted in parallel with the TMI-I restart activity. Since an occurrence as described above can only occur during power operation, such an occurrence has been precluded at TMI-I.
For these reasons we are requestine an extension to provide responses prior to restart of TMI-I.