T/G l

Alabama Power Company

, 600 North 18th Street g-yg Post Office Box 2641 Birmingham. Alabama 35291 Telephone 205 323-5341 b

F. L CLAY 10N, JR.

Ae Senior Vice President Mlabama Power the southem electrc sys*em December 4, 1979 Docket No. 50-348 1.E. Bulletin 79-OlA

~

Additional Response

.I s'

o

c...

c.a oc Mr. J. P. O'Reilly U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, N.W.

Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

Attached is additional response to I.E. Bulletin 79-01A as requested by your staff.

If you have questions, please advise.

3 Yours very truly, (ov%

F.

layton,t}r.

FLCJr/TNE:bhj Attachment cc:

Mr. R. A. Thomas Mr. G. F. Trowbridge 1660 261 791281 o g{ 7

.w GF ~ c

4 FARLEY '

SUPPLEMENTAL RESPONSE TO IE BULLETIN 79-01A (ASCO Solenoids)

Alabama Power Company submits the following supplemental response to IE Bulletin 79-01A. is a revised listing of valves in containment with ASCO solenoid valves. Additions to the listing submitted on June 13, 1979 are:

LCV-1003 -- Reacter Coolant Drain Tank Heat Exchanger Discharge HV-3766 -- Accumulator Tank Sample This list of solenoid valves (Attachment 1) was sent to ASCO for review.

From this review it was discovered that solenoid valves HV-8047, HV-8871 and HV-7126 contained acetal plastic parts and solenoid valves HV-3196, HV-3197, and LCV-1003 contained Buna N elastomer materials used as diaphragm, discs, and gaskets.

The solenoid valves on valves HV-8047, HV-8871, HV-7126, and LCV-1003 were replaced with solenoid valves not containing acetal plastic parts or Buna N materials. Attachment 2 is an updated list of ASCO solenoid valves in containment reflecting current solenoid valve catalog numbers.

Alabama Power Company has ensured that for all ASCO solenoid valves except HV-3196 and HV-3197 (Attachment 2):

(1) No parts of any solenoid valve contain acetal plastic material.

(2) No seals and gaskets of any solenoid valve contain Buna N material.

(3) All coils of solenoid valves are either HT or HB.

(4) All solenoid enclosures are at least a Nema 4 enclosure.

(5) A preventive maintenance program is being established for ACSO solenoid valves.

For valves HV-3196 and HV-3197 Alabama Power Company plans to replace the solenoid valves with ones that contain no Buna N materials.

It should be noted that a qualification test has been performed on HTX8210 solenoids by Fisher Valve. Results of this test indicate the HTX8210 solenoid can function for one hour at 320 F saturated steam and 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> at 2880F and be functionally and physically operable. This demonstrates closure of these valves can be achieved during accident conditions. Alabama Power Company has committed to keep valves HV-3196 and HV-3197 closed until they are fully qualified.

Also, during the walkdown of Farley-Unit 1 to determine types of solenoid valves, all of the solenoid valves for Henry Pratt 18" containment mini-purge valves were identified as containing high temperature coils, no acetal plastic parts, and no Buna N elastomer. This has been confirmed by Automatic Switch Company.

1660 262

SOLEN 0ID OPERATED VALVES IN FARLEY. UNIT 1 CONTAINMENT Valve Catal.og Number Number Title HV 3103 HTX8320A22V Pressurizer Sample Lines ATTACHMENT 1 HV 3104 HTX8320A22V Pressurizer Sample Lines HV 3184 HTX8316C45V CCW from RCP Thermal Barrier (PhaseB)

HV 3376 HTX8316C45V CTM Sump Discharge HV 3443 HTX8316C45V CCW from Letdown Heat Exchanger HV 3765 HTX8320A22V. Reactor Loop Sample Line HV 3766 HTX8320A22V Accumulator Sample Isolation HV 3196 HTX8210 CTMT Purge Isolation HV 2866B HTX8316C15E Mini Purge Isolation HV 28678 HTX8316C15E Mini Purge Isolation HV 3179A -

HTX8320A22V Steam Generator 1A Blowdown Sample Isolation HV 3179B HTX8320A22V Steam Generator 1A Blowdown Sample Isolation HV 3180A HTX8320A22V Steam Generator 1B Blowdown Sample Isolation MV 3180B HTX8320A22V Steam Generator 1B Blowdown Sample Isolation HV 3181A HTX8320A22V Steam Generator 1C Blowdown Sample Isolation HV 3181B HTX8320A22V Steam Generator 1C Blowdown Sample Isolation HV 3101 HTX8320A22V Reactor Coolant Hot Leg HV 3102 HTX8320A22V Reactor Coolant Hot Leg HV 3880 HTX8320A22V Pressure Steam Space Sample HV 3881 HTX8320A22V Pressure Liquid Space Sample HV 3179C HTX8320A22V Steam Generator lA Blowdown HV 3180C HTX8320A22V Steam Generator 1B Blowdown HV 3181C HTX8320A22V Steam Generator 1C Blowdown HV 3162 HTX8320A22V Accumulator Tank 1 Sample HV 3163 HTX8320A22V Accumulator Tank 2 Sample HV 3164 HTX8320A22V Accumulator Tank 3 Sample

  • HV 8047 LBX8316540 Pressurizer Relief Tank to Waste Processing System HV 8149A 206-381-6RF Chemical and Volume Control System Letdown Heat Exchanger Line HV 8149B 206-381-6RF Chemical and Volume Control System Letdow'n Heat Exchanger Line HV 8149C s 206-381-6RF Chemical and Volume Control System Letdown Heat Exchanger Line

~

  • Solenoids Replaced.

r

'~

SOLEN 0ID OPERATED VALVES IN FARLEY-UNIT 1 CONTAINMENT Valve Catalog iitle Number Number HV 3103 HTX8320A22V Pressurizer Sample Lines ATTACHMENT 2 HV 3104 HTX8320A22V Pressurizer Sample Lines HV 3184 HTX8316C45V CCW from RCP Thermal Barrier (Phase B)

HV 3376 HTX8316C45V CTMT Sump Discharge HV 3443 HTX8316C45V CCW from Letdown Heat Exchanger HV 3765 HTX8320A22V Reactor Loop Sample Line HV 3766 HTX8320A22V Accumulator Sample Isolation HV 3196

. HTX8210 CTMT Purge Isolation HV 2866B HTX8316C15E Mini Purge Isolation HV 2867B HTX8316C15E Mini Purge Isolation HV 3179A HTX8320A22V Steam Generator 1A Blowdown Sample Isolation HV 3179B HTX8320A22V Steam Generator 1A Blowdown Sample Isolation HV 3180A HTX8320A22V Steam Generator 1B Blowdown Sample Isolation HV 3180B HTX8320A22V Steam Generator 1B Blowdown Sample Isolation HV 3181A HTX8320A22V Steam Generator 1C Blowdown Sample Isolation HV 3181B HTX8320A22V Steam Generator 1C Blowdown Sample Isolation HV 3101 HTX8320A22V Reactor Coolant Hot Leg HV 3102 HTX8320A22V Reactor Coolant Hot Leg HV 3880 HTX8320A22V Pressure Steam Space Sample HV 3881 HTX8320A22V Pressure Liquid Space Sample HV 3179C HTX8320A22V Steam Generator lA Blowdown HV 3180C HTX8320A22V Steam Generator 1B Blowdown HV 3181C HTX8320A22V Steam Generator 1C Blowdown HV 3162 HTX8320A22V Accumulator Tank 1 Sample HV 3163 HTX8320A22V Accumulator Tank 2 Sample HV 3164 HTX8320A22V Accumulattr Tank 3 Sample

  • HV 8047 HTX8316C15E Pressurizer Relief Tank to Waste Processing System HV 8149A 206-381-6RF Chemical and Volume Control System Letdown Heat Exchanger Line HV 8149B 206-381-6RF Chemical and Volume Control System Letdow'n Heat Exchanger Line HV 8149C 206-381-6RF Chemical and Volume Control System Letdown Heat Exchanger Line

~

~

.