Forwards Final Deficiency Rept Re Defective Design of Charcoal Adsorber Trays
Date released: 09/27/2019 Download: ML19256G247


Final Deficiency Rept:On 791116,charcoal Absorber Trays Were Found to Leak Charcoal Between Frame & Perforated Plate. Caused by Design Defect Due to Poorly pop-riveted Joint. Trays Will Be Removed & Replaced
ML19256G251
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/14/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19256G251 (1)
Forwards Final Deficiency Rept Re Defective Design of Charcoal Adsorber Trays
ML19256G246
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/14/1979
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19256G246 (1)