05000338/LER-1979-158-01, /01T-0:on 791211,during Mode 5,S&W Notified Util That Nonseismically Qualified Pressure Differential Switch (PDS-HV1228A & B) Had Been Used in Condenser Water Controls in Control Room Air Conditioners

From kanterella
(Redirected from ML19256G193)
Jump to navigation Jump to search
/01T-0:on 791211,during Mode 5,S&W Notified Util That Nonseismically Qualified Pressure Differential Switch (PDS-HV1228A & B) Had Been Used in Condenser Water Controls in Control Room Air Conditioners
ML19256G193
Person / Time
Site: North Anna 
Issue date: 12/21/1979
From:
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19256G191 List:
References
LER-79-158-01T, LER-79-158-1T, NUDOCS 7912270588
Download: ML19256G193 (2)


LER-1979-158, /01T-0:on 791211,during Mode 5,S&W Notified Util That Nonseismically Qualified Pressure Differential Switch (PDS-HV1228A & B) Had Been Used in Condenser Water Controls in Control Room Air Conditioners
Event date:
Report date:
3381979158R01 - NRC Website

text

_

_y_

_ _.._ _._ m NRC FORM M6 U.S. NUCLEAR REGULATORY COMMISSION (7 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

lo ltl l Vl Al Nl A Sl1l@l Ol 0l -l 0] 0] 0l 0] 0l -l 0l Ol@l 4l 1l 1l 1l 1]@l l

l@

7 8 9 LICENSEE CODE 14 15 LICENSE NUMciEH 25 26 LtCENSE TYPE JO

$7 CAT 68 CON'T 10l1I s$g*CE X @l 0 l 5 l 0 l 0 l0 l 3 ] 3 l 8@l1 l2 l1 l1 l7 l9 @l1 l2 l2 l1 l7 l9 7

8 60 61 DOCK ET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 8C EVENT DESCRIPTION AND PROBASLE CONSEQUENCES h O

2 l On December 11, 1979, with the unit in Mode 5, Stone & Webster informed Vepco that a_I l non-seismically qualified pressure differential switch (PDS-HV1228 A and B) had been 1

O a

l used in the condenser water controls for the control and relay room air conditicners. I 0

4 e 's I a seismic category I system.

This discrepancy was discovered during the review re-

]

O s l quired by IEC 78-08.

The health and safety of the general public were not affected I

l 0 l 7 l l by this event.

Reportable pursuant to T.S. 6.9.1. 8.1.

I l

O a

l DE CODE SUSC DE COMPONENT CODE SUBCOD'E S

E Q

l A l A l@ lB l@ lA l@ W N l S l T l R l U lh l Slh J @

7 8

9 10 11 12 13 16 19 20 SEQU ENTI AL OCCURRENCE REPORT REVitf0N LER/RO SVENT YE AR R EPOR T No.

CODE TYPE N O.

RE l 7l 9l

_l l1l5 8]

y [0 l1 l W

[--j y

@ gu

_ 21 22 23 24 26 27 28 29 30 31 32 7 K N AC CN ON PLANT VET O HOURS 22 5B IT FOR b B.

SUPPLIE R MANUFACTURER lX lgl34Xlg Zlg l Zl@

0l 0l 0 0l WQ Nl@

lAl@

Cl7l5 3l@

35 36 31 40 41 42 43 44 47 33 CAUSE DESCPi= TION AND COR AECTIVE ACTIONS h i

O lIt is not "cown at this time why a non-seismically qualified switch was used in a l

re-l [i li l seismic category I system.

The pressure differential switch is presentiv being I

l1 12 I levaluated tnJtermine if replacement is necessary.

11 131 l I

1 1

4 80 7

8 9 ST U

,80AE4 OTHER STATUS

.SCO RY DISCOVERY DESCRIPTION Cl@ [ 0! C l O j@l NA l

lDl@l Notification from A/E l

s ACTIVITY CO TENT RELEASED OF RELEASE AVOUNT OF ACTIVITY LOCATION oF RJLEASE NA l NA l

]g gj 1

6 g l[P R

O h,

80 f

p 7

8 9 10 11 44 45 PERSGNNEL EXPOSURES u @j u l

NUVBER TYPE DESCRIPT* 0N O@

y l 0l 0l 0l@lZl@l t

a

=

2 u

' PE RSONN e'L iN2u'a,,,

oESCR.PTiOsq 164.2 035

~ uvu R I

li la l 01OlOl@l 80 7

8 9 11 12

=o' " rS=we

'^c" @

v 91227 o

^

bWl l'alLl@l NA 80 7

8 9 10

@OESCRIPTION J

llllllllllll2 ISSU Q

j NA 68 69 30 5 7

8 9 10

3 _ _._

Virginia Electric and Power Company North Anna Power Station, Unit #1

Attachment:

Page 1 of 1 Docket No. 50-338 Report No. LER 79-158/01T-0

Description of Event

On December 11, 1979, with the unit in a cold shutdown, Stone & Webster informed Vepco that during the review required by IEC 79-08 it had discovered that a non-seismically qualified switch had been used in a seismic category I system.

The switch concerned is PDS-HV1228A and B which is used in the con-denser water controls for the control and relay room air conditioning system.

Probable Consequences of Occurrence A probable consequence of this event is that the switch could fail during an earthquake and jeopardize the proper operation of the control and relay room air condicioners.

The health and safety of the general public have not been endangered by this occurrence.

Identical pressure dif ferential switches are used in Unit 2's air conditioning system and is therefore simi-larly affected.

Cause of Occurrence The reason for the non-seismically qualified switch being used in a seismic category I system is not known at this time.

Immediate Corrective Action

The pressure dif ferential switch is prest itly being re-evaluated to determine if replacement is necessary.

Scheduled Corrective Action If replacement is required, an equivalent switch with seismic qualifica-tions will be installed in place of PDS-HV1728 A and B.

Actions Taken to Prevent Recurrence No further actions are required.