ML19256G115
| ML19256G115 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 12/18/1979 |
| From: | Mills L TENNESSEE VALLEY AUTHORITY |
| To: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| Shared Package | |
| ML19256G116 | List: |
| References | |
| NUDOCS 7912270473 | |
| Download: ML19256G115 (1) | |
Text
T TENNESSEE VALLEY AUTHORITY CH ATTANCOGA. TENNESSEE 374o1 400 Chestnut Street Tower II December 18, 1979 Mr. James P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region 11 - Suite 3100 101 Marietta Street Atlanta, Georgia 30303
Dear Mr. O'Reilly:
SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 - DIESEL GENERATOR FIELD RELAY COIL (Kl) FAILURES - NCR 15P - FINAL REPORT The subj ect deficiency was initially reported to NRC-01E Inspector
'i. T. Cottle on August 27, 1979, in accordance with 10 CFR 50.35(e).
An interia report was submitted on September 26, 1979.
Enclosed is our final report.
If you have any questions ccncerning this matter, p'2ase get in touch with D. L. Lambert at FIS 854-2581.
Very truly yours, IENNESSEE VALLEY AUTHORITY I
,,n.,
e L. M. Mills, Managcr Nuclear Regulatior and Safety Enclosure cc:
Mr. Victor Stello, Jr., Director (Enclosure)
Office of incpection and Inforcement U.S. Nuclear Regulatory Commission
'4ashington, DC 20555 6
1644 319
%\\
\\
~ s-c _,. s c, -
2912220